3-3 Degree of match inspection for shape and size

Below is an example of an operation to determine the degree of match of the images 0 and 1, and the
coordinates of the detection points with respect to the following object.
Detection point 0
(1) Operation on the MAIN OPS MENU (after initialize all conditions)
MAIN OPS MENU
(TYPE00)
MEAS.
MEAS0 CAM1 NO
X0~6
:
MSR-CHNG REG-CHNG PC-MONTR SET-SCRN MANL-TYP-CHG
1. Move the cursor to [SET-SCRN] item and press the SET key.
- The [SYSTEM SETUP] menu will be displayed.
(2) Operation on the [SYSTEM SETUP] menu
[SYSTEM SETUP]
1OPS MENU SETTING (TO NEXT SUB-MENU)
2OBJECT TYPE COND (TO NEXT SUB-MENU)
1
3I/O CONDITIONS
4ADJ. CAM POSITION (TO NEXT SUB-MENU)
5DISPLAY MODE
6RECEIVING PARMS
7INIT ALL PARMS
8SELF DIAGNOSTICS EXEC
9SAVE IN FLASH MEM EXEC
0OPERATIONS
1. Move the cursor to 2 OBJECT TYPE COND (conditions of object type) and press the SET
key.
- The [OBJECT TYPE COND] menu will be displayed.
Continued on the following page
Image 0
ms
Y0~7
BUSY
:
1
(TO NEXT SUB-MENU)
JAPANESE ENGLISH
EXEC
EXEC
3-15
Operation Examples (Degree of match inspection)
Image 1
Detection point 1
Object to be measured
F L C1ALLC2NO
VX.X
:
F C1 H
3