(2) Measurement number switching terminals X5 and X6
If item 4 CHG MEAS NO. X5, X6 on the [I/O SETTINGS] menu has been set to "YES," the
measurement program numbers (in combination with measurement number 0) can be specified
from the following 4 combinations by turning ON or OFF the input terminals (INPUT) X5 and X6.
[I/O SETTINGS]
1 MEAS TRIG INP I/F PARALLEL SERIAL CCD-TRIG
4 CHG MEAS NO.X5,X6 NO YES
11-2 Measurement start input and result output settings
The combinations of various settings for item 1 MEAS TRIG INP I/F, item 2 START CCD
SAMPLE, and item 3 SERIAL OUTPUT (OUTPUT OBJ. TYPE) on the [I/O SETTINGS] menu
(page 11-1) are explained below.
Measurement
start input IF
· Parallel
· General purpose
serial
· CCD trigger
The time required to change object types is calculated differently according to the type of measurement
start input I/O, as follows:
Measurement start input I/F
Parallel I/O
General-purpose serial
CCD trigger
Set to "YES."
Result output
Parallel
(1)
Computer link/parallel
General purpose serial/parallel
General purpose serial/parallel
Object type
Start sampling
Parallel
(Parallel)
General purpose
(General purpose
serial
Auto
General purpose
Time to change object type
Included in the measurement execution time
Not included in the measurement execution time
Not included in the measurement execution time
11-3
Setting the Input/Output Conditions
Measurement program
Measurement 0
Measurement 0 & 1
Measurement 0 & 2
Measurement 0 & 3
(2)
(3)
(4)
change
Result output
Parallel
Computer link/parallel
General purpose serial/parallel
General purpose serial/parallel
serial)
Parallel
Parallel
General purpose serial/parallel
serial
X6
X5
OFF
OFF
OFF
ON
ON
OFF
ON
ON
(5)
(6)
(7)
(8)
(9)
(10)
11