(3) Ladder circuit 2 (setting output signals)
[RESULTS OUTPUT]
1PAGE.NO.
2SET POSITION
1
3INPUT SIGNAL
4LOGICAL SYMBOL
5OUTPUT SIGNAL
2
6UPPER MENU
[PAGE0]
INPUT0
LOGIC
INPUT1
LOGIC
INPUT2
LOGIC
INPUT3
LOGIC
1. Move the cursor to item 2 SET POSITION with the up and down keys, and press the SET key.
- Move the cursor to the row where a ladder circuit output relay will be placed, and press the SET
key. An output relay can only be placed only on rows where input signals have already been
placed.
2. Move the cursor to item 5 OUTPUT SIGNAL with the up and down keys, and press the SET
key.
3. Select the kind of output signal and the number (set value). After moving the cursor to the
desired output signal with the left and right keys, select a number (set value) with the up and
down keys, and press the SET key.
- The output symbol and signal will be displayed on the row specified in step 1.
Display example:
[PAGE0]
INPUT0
LOGIC
Continued on the following page
(TYPE00)
(0~7) REG.NO YES
MOVE
AUXRLY C112(0~127) EXT-INP X0(0~6)
TMR TM0(0~7) CNT CN0(0~7)
AN00(0~15) OUT Y00(0~15)
OUT Y00(0~15) AUXRLY C000(0~127)
TMR TM0(0~7) SET-VL000(000~999)
CNT CN0(0~7) SET-VL000(000~999)
DEL.
0
1
2
3
4
5
C000
0
1
2
3
4
C000
10-11
DEL.
6
7
OUT
5
6
7
OUT
Y00
PC Function