(2) Copying between measurement programs
Copying a specific measuring program's settings from on object type number to another.
The source of the copy
The specific measuring program
settings stored in a particular
object type number. (The data is
copied from flash memory)
[The procedure for copying measurement program 0]
- Example: Copying the (object type number 00, measurement 0, program settings: for
positional deviation measurements) into the settings for (object type number 01,
measurement 0, program setting no).
On the MAIN OPS MENU, move the cursor to SET-SCRN item, and press the SET key.
- On the [SYSTEM SETUP] menu, move the cursor to 2 OBJECT TYPE COND
(conditions of object type) and pess the SET key.
- On the [OBJECT TYPE COND] (conditions for object type) menu, set item 1
OBJECT TYPE NO. (object type number) to 01 and select item 4 MEAS.0,
CAMERA1.
1
4
1.Select item 2 COPY using the up and down keys and press SET key.
2.Enter the object type number (00 to 15) for the source copy using the up and down keys. The
name of the measurement program for this object type number will also be displayed. When
the number has been entered, press the SET key.
3.Once the measurement program has been copied, the underlined entry at item 1 SELECT
MEAS.TYPE (select measurement) will now be MEAS-POSITION-DEVIATE (positional
deviation measurement) whereas NO was previously underlined.
4.Move the cursor to item 8 UPPER MENU, and press SET key twice.
- This will return you to the [OBJECT TYPE COND] menu.
Note
- When processing item 2 COPY, by itself, the IV-S20 will not copy to the flash memory.
To save the copied settings in flash memory go to item 9 SAVE IN FLASH MEM, or item 0
OPERATIONS, which are both found on the [SYSTEM SETUP] menu.
[TYPE01-MEAS0]
1SELECT MEAS. TYPE
NO MEAS-POSITION-DEVIATE
2COPY :
EXEC TYPE00 CMR1POS-DEVIATION
3INITIALIZATION
EXEC
4MEAS. PROG. COND
(TO NEXT SUB-MENU)
5EVALUATION COND
(TO NEXT SUB-MENU)
6NUMERIC CALC COND
(TO NEXT SUB-MENU)
7OUTPUT CONDITIONS
(TO NEXT SUB-MENU)
8UPPER MENU
9-29
The target of the copy
The settings for the same measuring
program in a different object type
number. (The data is used to simplify
setting the target object's parameters)
Shared settings
3
2
9