Image Settings - Sharp IV-S20 User Manual

Compact image sensor camera
Table of Contents

Advertisement

Shared settings

[2] Image settings

What follows is a description of how to use the image settings to control the measuring program.
(1) Gray scale processing (pixel contraction and detection precision)
[Settings menu screen]
· Positional deviation measurement
(gray scale search)
Degree of match inspection for shape
and size (gray scale processing).
5CONTR. PIXEL (MDL 0) 1 2 3
0CONTR. PIXEL (MDL 1) 1 2 3
qDETECT ACCURACY
50CONTR.
9
qDETECT
ACCURACY
(detection
precision)
· To increase the speed of your search, you must take into account the settings listed
below.
1. When using the high precision setting, a smaller image should be used.
2. Reduce the size of the scanned image.
3. After considering what the maximum out of position dimension would be, make the
search area as small as possible.
4. If the size of the object is larger than 8 pixels then set the pixel contraction to 3.
[Measurement programs which are affected by these settings]
Positional deviation measurement (gray scale search: page 9-37)
Degree of match inspection for shape and size (gray scale processing: page 9-48)
Distance and angle measurement (gray scale search: page 9-60)
Lead inspection (criteria search: page 9-75)
STANDARD HI-PRC
Menu
· 1: Search the scanned image in groups of 2 pixels.
PIXEL
· 2: Search the scanned image in groups of 4 pixels.
(pixel
· 3: Search the scanned image in groups of 8 pixels.
contraction)
· STANDARD (standard): Detection precision of 1 pixel unit
· HI-PRC (High precision): Detection precision of 1/10 pixel
Reference image
(Standard)
Search coordinates
use a 1 pixel level
of precision
Degree of
match
High precision
pixel detection
Point of detection
· Distance and angle measurement (gray
scale search)
Lead inspection (criteria search).
5CONTR. PIXEL(MDL0)
qDETECT ACCURACY
Description
level
unit level
(High precision)
Search coordinates use a
sub-pixel level of precision (1/10)
0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
Standard pixel
Camera image
detection
Pixel
Point of detection
9-6
1 2 3
STANDARD HI-PRC
Degree of
match