Sharp IV-S20 User Manual page 285

Compact image sensor camera
Table of Contents

Advertisement

(10) Measurement start input = CCD trigger, start sampling = auto, object type change =
general purpose serial, result output = general purpose serial/parallel
The general purpose serial command (code 55
· Setting order 1
[I/O SETTINGS]
1 MEAS TRIG INP I/F PARALLEL SERIAL CCD-TRIG
2 START CCD SAMPLE AUTO (EDGE LEVL) PARALEL SERIAL
3
(CCD SAMPLING AUTOMATIC)
8 SERIAL CONDITIONS (TO NEXT SUB-MENU)
Settings listed in section
11-3 "CCD trigger"
(H)
2
3
8
PARALLEL SERIAL
Select one of
the following.
Measurement is started when the CCD trigger level is ON.
Measurement is started when a CCD trigger signal is received.
Measurement
11-15
Setting the Input/Output Conditions
) is used to change the object type.
· Configuration example
Camera 1 (image capturing + CCD trigger)
Camera 2 (image capturing)
Personal computer
Data
Remote key pad
IV-S20 main housing
Power supply (24 VDC)
Black White
Work
CCD trigger
Edge
Level
Monitor
11