Connecting A Power Supply - Sharp IV-S20 User Manual

Compact image sensor camera
Table of Contents

Advertisement

Installation Conditions and Method

[3] Connecting a power supply

Connect a commercially available constant-voltage power supply to the power terminals (POWER:
+24 V, 0 V) on the IV-S20 main housing.
Use a 24 VDC ± 10%, 350 mA or more constant-voltage power supply.
- Use an individual power supply to supply power to the IV-S20 main housing. If the power supply is
used to power other equipment, measurement errors may occur.
- Check the polarity of the power supply terminals, +24 V and 0 V. If power is supplied with the polarity
inverted, the IV-S20 main housing may be damaged.
- Only connect or disconnect the camera cable and other equipment while the power is OFF.
6
Note
To improve the noise resistance of the constant-voltage power supply connected to the
IV-S20 main housing, observe the following precautions.
- Ground the FG terminal of the constant-voltage power supply according to the class 3
- The power line between the IV-S20 main housing and the constant-voltage power supply
- Use twisted-pair wire for the power supply line.
Constant-voltage
power supply
Fuse
(1A)
Power supply terminal
(POWER: + 24V)
INPUT
X0
X1
X2
X3
X4
X5
Y0
Y1
Y2
Y3
Y4
OUTPUT
INPUT
POWER
X0
X1
X2
X3
X4
X5
X6
C(+)
+24V
0V
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
BUSY
OUTPUT
VIDEO CAMERA1 CAMERA2
RS232C/RS422
grounding.
must be as short as possible. (Recommended distance: less than 30 cm)
Do not run the power supply line near any noise generating sources, such as electric
motor lines.
24 VDC
(+)
(-)
POWER
X6
C(+)
+24V
0V
Y5
Y6
Y7
BUSY
C(-)
IV-S20 main housing
IV-S20
POWER
C(-)
REMOTE
6-12
Frame ground
terminal
Frame ground
terminal
Power supply terminal
(POWER : 0V)
This distance must be
as short as possible.
(Recommended distance:
less than 30 cm)

Advertisement