Sharp IV-S20 User Manual page 57

Compact image sensor camera
Table of Contents

Advertisement

Operation Examples (Lead inspection)
Continued from the preceding page
(9) Operation on the [EVALUATION CONDITION] (evaluation condition) menu
1. Move the cursor to 7 EVALUATION CONDITION with the up and down keys, and press the
SET key.
- The [EVALUATION CONDITION] menu will be displayed.
[EVALUATION CONDITION]
2
3
3
4
5
6
2. Move the cursor to 1 REGST NO. (registration number) with the up and down keys, and
press the SET key. Enter the number "0" with the up and down keys, and press the SET key.
3. Move the cursor to 4 MATCH (degree of match) with the up and down keys, and press the
SET key.
4. Move the cursor to the lower limit position with the right and left keys, and press the SET key.
- Select a digit with the right and left keys, and then set the value to +09000 with the up and
down keys.
(Criteria for successful match: 90.00% to 100.00%)
- After defining the lower limit, press the SET key and ESC key.
5. Move the cursor to 6 NUMBER with the up and down keys, and press the SET key.
- Move the cursor to the lower limit position with the right and left keys, and enter the value to
"005" with the up and down keys.
- Move the cursor to the upper limit position with the right and left keys, and enter the value to
"005" with the up and down keys.
- After defining the lower and upper limit, press the SET key.
6. Move the cursor to 0 UPPER MENU with the up and down keys, and press the SET key.
- The screen will return to the [TYPE00-MEAS1] (type: 00, measurement: 1) menu.
7. Press the ESC key.
- The screen will return to the [OBJECT TYPE COND] (conditions of object type) menu.
(10) Setting the final evaluation output condition
This setting is used to output the result of the final evaluation externally (see the following page).
- The final evaluation result is always output to the auxiliary relay C112. When the final
evaluation result is OK, C112 is ON, and when the result is NG, it is OFF. The result of final
evaluation can be externally output by using the auxiliary relay C112.
- The setting procedures are the same as described in item (9) in section 3-2 "Position
measurement."
PAGE0]
INPUT0
LOGIC
Continued on the following page
1REGST NO.
0(0~3)
2X COORD
000.0~511.0
3Y COORD
000.0~479.0
4MATCH
-10000~ +10000
5MEAS OBJ
CRT.0-0(0~7)
6NUMBER
000~128
7DISTANCE
000.0~702.0
9MAKE A TEST RUN
(SET KEY)
0UPPER MENU
4MATCH : +09000~ +10000
6NUMBER : 005~005
0
1
2
C112
(TYPE00-MEAS.1-INSPECT LEAD)
3
4
5
6
7
OUT
Y00
3-36
[OUT]
NO
NO
NO
NO
NO