Sharp IV-S20 User Manual page 274

Compact image sensor camera
Table of Contents

Advertisement

Setting the Input/Output Conditions
(1) Measurement start input = parallel, object type change = parallel, result output = parallel
· Setting order 1 (
[I/O SETTINGS]
1
3 SERIAL OUTPUT
(INPUT=PARALLEL)
- Time chart
Measurement
start input
(X0)
Object type
number input
(X1 to X4)
11
BUSY output
PC calculation
condition
Parallel output
(Y0 to Y7)
3)
PARALLEL SERIAL CCD-TRIG
NO PC-LINK SERIAL
- The conditions for outputting the results to the output signals Y0 to Y7 are set by the PC
function. (See Chapter 10 "PC Function.")
10 ms
or more
10 ms
10 ms
or more
or more
Specified object type number
P
P
P
P
Halt PC operation during
C
C
C
C
measurement
When the object type is
changed, all Y output and
auxiliary relays turn OFF.
· Configuration example
Camera 1 (image capturing)
Camera 2 (image capturing)
Remote keypad
IV-S20 main housing
Power supply
(24 V DC)
Warning lamp
External output
(Y0 to Y7)
Specified object type number
Measurement result is valid at the end
of a measurement
P
P
P
P
P
P
P
P
Halt PC operation during
C
C
C
C
C
C
C
C
measurement
Parallel output is valid for PC control
after the measurement result is
determined.
Result output
11-4
Monitor
External trigger X0
(photo sensor or
proximity sensor)
Type selection switch
(X1 to X4)
P
P
P
P
P
C
C
C
C
C
Result output

Advertisement