Distance and angle measurement
Continued from page 9·59: Setting the DST & AGL MES. (measurement of distance and angle) for GRAV.
(center of gravity operations).
[MEASURING COND] (TYPE00-MEAS.1-DST&ANGL MEAS)
1START POINT COND
2AUX.CONDITIONS
3DISTANCE CONDITIONS (TO NEXT SUB-MENU)
4ANGLE CONDITIONS
5UPPER MENU
Select item 1 START POINT COND (starting point conditions)
1MEAS WINDOW TYPE RECTANGLE CIRCLE ELLIPSE
2MEAS WINDOW POSIT MOVE UP.L(224,208) LO.R(287,271)
3MASK WINDOW TYPE NO RECTANGLE CIRCLE ELLIPSE
4MASK WINDOW POSIT MOVE UP.L(224,208) LO.R(287,271)
5THRESHOLD VALUE U.LM 255 L.LM 100(0~255)
6INVERT B/W
7BINARY PROCESS FIXED THRSHOLD-ADJ (VAR-DIFF VAR-RATE)
8BOUNDARY PROCESS VALD INVLD
9LABEL ORDER
0IMAGE PRE-PROCESS OFF SMOOTH EDGE-EMPHASIS
qBINARY NOIS FILTR NO EXP. CONTR. CONTR. EXP.
wNUM. OF FILTR PASS EXPD.0(0~5) CONTR0(0~5)
eAREA FILTER
rUPPER MENU
· Item 4 will be displayed unless item 3 is set to NO.
1MEAS WINDOW TYPE
9
(measurement window)
2MEAS WINDOW POSIT
(measurement window
position)
3MASK WINDOW TYPE
4MASK WINDOW POSIT
(mask window position)
5THRESHOLD VALUE
6INVERT B/W
(black and white inversion)
7BINARY PROCESS
(binary conversion process)
8BOUNDARY PROCESS
(boundary processing)
9LABEL ORDER
0IMAGE PRE-PROCESS
Continued on the following page
(TO NEXT SUB-MENU)
(TO NEXT SUB-MENU)
(TO NEXT SUB-MENU)
NO YES
SACN-ORDER SIZE ORDER
ALL-EDGE HORZ-EDGE VERT-EDGE
000000PIXEL LOWER LIMIT
Menu
Select measurement window type: RECTANGLE (rectangular), CIRCLE
(circular) or ELLIPSE (elliptical).
Set the size and position of the window in units of 1 pixel.
· If circle or ellipse is selected in item 1, then the two variables you must
set are the center and diameter.
Decide whether a mask window will be employed and if so which type
(rectangular, round or elliptical).
· A mask window exists inside the boundary of the measurement window
and screens out those parts of the image which are not needed for the
measurement process.
Set the size and position of the mask window (which is drawn with a dotted
line) using units of 1 pixel.
· If a circle or an ellipse is selected in item 1, then the two variables you
must set are the center and diameter.
· The mask window can be set exceeding the measurement window.
Set the upper and lower limits for binary conversion, within the range of 0 to
255.
-See page 9·7, Setting threshold values, in shared settings.
Set the inversion of black and white in the image to YES or NO.
· NO means the white area will be measured after the image has been
converted to binary values.
· YES means the black area will be measured after the image has been
converted to binary values.
Select either fixed or threshold value correction as the binary conversion
processing method. (VAR-DIFF or VAR-RATE).-See methods for binary
conversion in shared settings on page 9·8.
Enable or disable boundary processing.
-See setting the window boundary in shared settings on page 9·7.
Select the labeling order.
-See labeling order in shared settings on page 9·8.
Select a method for pre-processing image data.
-See pre-processing in shared settings on page 9·9.
Setting details
9-62
This is how the display looks
when item 1 MEAS WINDOW
TYPE is set to RECTANGLE.
This is how the display looks
when item 3 MASK
WINDOW TYPE, is set to
RECTANGLE.