Sharp IV-S20 User Manual page 58

Compact image sensor camera
Table of Contents

Advertisement

Continued from the preceding page
(11) Returning to the MAIN OPS MENU
1. Press the ESC key.
- The screen will return to the [SYSTEM SETUP] menu.
- Move the cursor to 9 SAVE IN FLASH MEM (save data in flash memory) or 0
OPERATIONS with the up and down keys, and press the SET key.
- The following message will be displayed on the upper part of the screen.
DATA SAVE? (Do you want to save data ?) (YES=[MOVE]/NO=[ESC])
- Press the SET key.
- The data saving operation will start, and the progress will be displayed on the bottom
of the screen.
When the data has been saved in the IV-S20 flash memory, the display will change from
"SAVING" to "SAVING COMPLETE."
Note:
· If the ESC key is pressed, the settings you entered will not be saved in the IV-S20
flash memory. In this case, if the power to the IV-S20 main housing is turned OFF, or
if the type No. is changed, the settings will be deleted.
2. Press the ESC key.
- The screen will return to the MAIN OPS MENU.
- If the cursor was moved to 0 OPERATIONS in step (11) above, the screen will
automatically return to the MAIN OPS MENU.
(12) Inspecting the lead
Press the TRG/BRT key, and the number of leads, lead pitches (max. and min. distances), the
center coordinates and the degree of match with the reference image will be displayed.
(TYPE00)
OK
MEAS. XXXXXXms
MEAS1 CAM1 INSPECT LEAD
REGST NO. 0(0~3)
X COORD 202.0
Y COORD 281.0
MATCH
+09957 OK
MEAS OBJ 0-0(0~7)
NUMBER 005
DISTANCE 040.0
039.0
*2
X0~6
:
MSR-CHNG REG-CHNG PC-MONTR SET-SCRN MANL-TYP-CHG
*1
The final evaluation result will be displayed as "OK" in the upper left corner of the screen when
all of the items have been evaluated acceptable. If there is a single unacceptable item, "NG"
will be displayed.
*2
When the final evaluation result is OK, Y0 is turned ON, and a filled box is displayed. (When
the result is NG, an empty box is displayed.)
When the auxiliary relay C112 is turned ON, Y0 is turned ON according to the condition set in
step (10) for final evaluation output.
REFERENCE IMAGE
SYSTEM I/O
MEAS CONDITIONS
OK
OK
OK
OK
Y0~7
BUSY
:
3-37
Operation Examples (Lead inspection)
F H C1ALLC2NO
[Display of inspection result]
VX.X
Final evaluation result (*1)
Measuring time
Center coordinates of reference
image and judgment results
Degree of match with the
reference image
Number of leads
Lead pitches
Upper: Max. distance (pixel count)
Lower: Min. distance (pixel count)
:
3

Advertisement