Sharp IV-S20 User Manual page 223

Compact image sensor camera
Table of Contents

Advertisement

Area measurement by binary conversion
Continued from the previous page
Select item 7 EVALUATION COND (evaluation condition) on the [TYPE00-MEAS 1 to 3] menu.
[EVALUATION COND]
1REGST NO.
2AREA
3MAKE A TEST RUN (SET KEY)
4UPPER MENU
Items 2 and 3 will be displayed if the REGST NO. (registration number) is set to YES on the
[MEASURING COND] menu.
Evaluation conditions
1REGST NO.
(registration number)
2AREA
3
4PRIOR MENU
· Check your selection by testing the upper and lower limits for evaluations that you have set.
This can be done using item 3 MAKE A TEST RUN.
· For more information about evaluation conditions, see section 9-2 [3] Evaluation condition.
9
Return to the [TYPE00-MEAS1 to 3] menu and select item
8 NUMERIC CALC COND (numerical calculation conditions).
Continued on the following page
(TYPE00-MEAS.1-MEAS-BIN-AREA)
00(0~15)
[TEST RESULT]
000000~245760
Select any number from 0 to 15.
Set the range for the area that will produce an OK evaluation.
TEST RUN
Pressing the SET key will test the evaluation condition, display
the test results.
This will return you to the [TYPE00-MEAS1 to 3] menu.
[OUT]
002000
OK
NO
Setting details
9-86
These displays can be set using
the up and down keys. (The
choices are NO, Y0 to 7, C000
to C127)

Advertisement

Table of Contents
loading

Table of Contents