This section describes the names and functions of the IV-S20 main housing, the camera (camera lens ,
camera body, and camera cable), and the remote key pad which comprise the IV-S20 system. See
section 6-2 and 6-3 for details about the housing brackets, camera angle bracket, and conversion
connector.
5-1 IV-S20 main housing
IV-S20 main housing (front)
IV-S20 main housing (side)
4 Monitor connector (VIDEO)
5 Camera 1 connector
(CAMERA1)
6 Camera 2 connector
(CAMERA2)
I/O terminal block
1
INPUT: X0 to X6, C (+)
OUTPUT: Y0 to Y7, BUSY, C (—)
Power terminal block
2
(POWER:
3
Power lamp (POWER)
Monitor connector
4
(VIDEO)
5
Camera 1 connector (CAMERA1)
6
Camera 2 connector (CAMERA2)
Communication connector
7
(RS232C/RS422: 9-pin, D-sub,
female, rock screw M2.6)
Remote key pad connector
8
(REMOTE)
9
Frame ground terminal
9 Frame ground terminal
2 Power terminal block
1 I/O terminal block
INPUT
X0
X1
X2
X3
Y0
Y1
Y2
VIDEO CAMERA1 CAMERA2
Name
The block has 7 input terminals and 9 output terminals.
- External devices are connected to these terminals for input
and output (parallel I/F).
_ See page 6-14.
Commercially available constant-voltage power supply (24 V
DC
24V, 0V)
_ See page 6-12.
When the power is applied to the IV-S20 main housing, the
green lamp will light.
A monitor is connected here.
- The monitor connector is an RCA jack.
The camera cable connector is connected here.
- The camera connected to the CAMERA 1 position is
camera 1, and the camera connected to the CAMERA 2
position is camera 2.
This connector is used to connect a personal computer for
communications (general purpose serial I/F) or to connect a
programmable controller for a computer link.
_ See page 6-16.
The remote key pad connector is used to make selections
from the menues on the screen (to set parameters). It is
connected here.
Be sure to ground the housing frame ground terminal
together with the frame ground of the constant-voltage
power supply in accordance with class 3 grounding
procedures. _ See page 6-12.
5-1
S2.09 mark
(software version 2.09)
IV-S20
POWER
POWER
X4
X5
X6
C(+)
+24V
0V
Y3
Y4
Y5
Y6
Y7
BUSY C(-z)
OUTPUT
3 Power lamp (POWER)
RS232C/RS422
REMOTE
8 Remote key pad connector
(REMOTE)
7 Communication connector
(RS232C/RS422)
Function
10%, 350 mA or more) is connected here.