Sharp IV-S20 User Manual page 249

Compact image sensor camera
Table of Contents

Advertisement

Existence inspection by point measurement
From page 9-110: When AV-LIGHT-LEVEL (average light level) is selected for the processing mode.
[EVALUATION COND] (TYPE00-MEAS.1-POINT-MEAS)
1 CHG PAGE TEST RUN
2 P000 :
3 P001 :
4 P002 :
5 P003 :
6 P004 :
7 P005 :
8 P006 :
9 P007 :
0
q MAKE A TEST RUN (SET KEY)
w UPPER MENU
Evaluation condition
1 CHG PAGE
(page change)
2 P
-
-
9 P
0 STORE ALL
COND
9
q MAKE A
TEST RUN
w UPPER MENU
- Set the measurement value (range of the average light level) that will produce a result of OK
in item q MAKE A TEST RUN.
Return to the [TYPE00-MEAS1 to 3] menu, and select item 9 OUTPUT CONDITIONS.
Continued on the following page
[TEST RESULT]
000~255
100
OK
000~255
100
OK
000~255
100
OK
000~255
100
OK
000~255
100
OK
000~255
Point numbers 2 to 9 can be displayed as groups of 8 objects, using
the up and down keys. Pressing the SET key will test the evaluation
conditions, display the test. results.
Set the range of the average light level for all point numbers from 0 to
127.
- The numbers of the selected point will flash.
- No light level is displayed for unregistered point numbers.
The light level is collectively averaged for all of the point numbers that
have been registered.
Pressing the SET key will test the evaluation conditions, display the test
results.
This will return you to the [TYPE00-MEAS1 to 3] menu.
9-112
Average light level of the points
OK/NG judgment
[OUT]
Æ OK when the average light level of a
NO
point is within the range set. NG when
NO
it is outside the range.
NO
These displays can be set using the up
NO
and down keys. (The choices are NO,
NO
Y0 to 7, or C000 to C127.)
Not displayed for point numbers which
have not been previously registered on
the point setting menu.
Setting details