Options 17 - 19
Option 17 – Instant Part
Selecting this option immediately sets all zones that have the part attribute enabled. No sounder or exit time is
involved.
NOTE: The zones must be closed to allow the system to part set. If any zones are open, then the exit time
reset feature (detailed previously) is activated.
Option 18 – Home Set
The Home Set option either fully sets or part sets the system. The system is:
fully set if the exit time is manually terminated via a Final or Push-Set zone operation;
part set if the exit time is allowed to expire.
Option 19 – All Set (Galaxy 18, 60, 128, 500, 504 & 512)
All Set allows a timed set of groups assigned to the user code without offering the choice of which groups are
to be set. No group choice is offered. The groups that are set when this option is selected is determined by the
keypad group restriction (refer to option 58.7 = KEYPADS.Groups):
If there is no keypad group restriction then all of the groups assigned to the user are set — as long as
there is at least one common group assigned to the keypad.
If there is a group restriction on the setting keypad, then only the groups that are common to both the user
and the keypad on which the menu option is selected are set. For example, a user assigned groups 1, 2, 3,
and 4 selecting the All Set option on a keypad assigned groups 2 and 3 will only set groups 2 and 3.
Galaxy Programming Manual
16