Silent Part (17 ent)

Use this option to set all zones that have the part attribute enabled. There is a
normal timed exit procedure without sounders. In the event of an alarm occurring
during a Silent Part set, for example a fire alarm, the system reverts to normal
operation.
When group mode is enabled, setting of a group using Silent Part set does not
affect the operation of any other group setting options.
Unsetting from Silent Part results in a double beep.

Home Set (18 ent)

Use this option to either fully set or part set the system. The system is:
Fully set if the exit time is manually terminated via a Final or Push-Set zone
operation.
Part set if the exit time is allowed to expire.

All Set (19 ent)

Use this option to start a timed set of all groups assigned to the user code. No
group choice is offered. The keypad group restriction determines the groups that
are set when this option is selected:
If there is no keypad group restriction then all of the groups assigned to the
user are set – as long as there is at least one common group assigned to the
keypad.
If there is a group restriction on the setting keypad, then only the groups that
are common to both the user and the keypad on which the menu option is
selected are set.

Display Zones (21 ent)

Use this option to show the status of each individual detection zone on the system.
On entering the option, the first system zone is displayed as shown below:
1001
ZONE1
On the top row, the zone address is shown along with the current status (open,
closed, etc) and toggles with the zone function.
status
CLOSED
function
1001
ZONE1
FINAL
17