TABLE 12–2
(continued)
Variable
Setting
true
n
diag-passes
diag-targets
none
iopath
media
device
loopback
loopbacks
loopback2
loopback3
nomem
device&loopback Runs built-in self-test (BIST) on
device&loopbacks Not for use on Enterprise 250
Description
Causes OBDiag to run all subtests
within a test, even if an error is
detected.
Repeats each test the number of
times specified by n. Works with
the test, except, and test-all
commands.
Runs internal tests only, no I/O
testing.
Extends testing to external device
interfaces (connectors/cables).
Extends testing to external devices
and media, if present.
Invokes built-in self-test (BIST) on
PCI cards and external devices.
Runs external loopback tests on the
parallel, serial, keyboard, mouse,
TPE, and RSC serial ports.
Not for use on Enterprise 250
servers.
Not for use on Enterprise 250
servers.
Runs external loopback tests on the
RSC Ethernet port
Performs tests without testing
system memory.
PCI cards and external devices,
then runs external loopback tests
on the parallel, serial, keyboard,
mouse, TPE, and RSC serial ports.
servers.
Diagnostics and Troubleshooting
Default
1
none
243