TABLE 12–2
Variable
diag-trigger
diag-
verbosity
OBDiag Test Descriptions
The following table provides information about the tests available through OBDiag.
It provides the test name, a brief description of the test, and any special
considerations involved in running the test.
Sun Enterprise 250 Server Owner's Guide ♦ Revision A, June 1998
244
(continued)
Setting
Description
Runs built-in self-test (BIST) on
device&loopback,3
PCI cards and external devices,
then runs external loopback tests
on the parallel, serial, keyboard,
mouse, TPE, RSC serial, and RSC
Ethernet ports.
Runs diagnostics only on power-on
power-reset
resets.
Runs diagnostics only on power-on
error-reset
resets, fatal hardware errors, and
watchdog reset events.
Runs diagnostics on all resets
soft-reset
(except XIR).
Prints one line that indicates the
0
device being tested and its pass/
fail status.
Prints more detailed test status,
1
which varies in content from test to
test.
Prints subtest names.
2
Prints debug messages.
4
Prints back trace of callers on error.
8
Default
power-reset
0