TABLE 12–1
Command
except #,#,
what #,#,
OBDiag Configuration Variables
The following table provides information about OpenBoot PROM configuration
variables that affect the operation of OBDiag. Use the printenvs command to show
current values and the setenv command to set or change a value. Both commands
are described in "OBDiag Commands" on page 241.
TABLE 12–2
Variable
diag-level
diag-
continue?
Sun Enterprise 250 Server Owner's Guide ♦ Revision A, June 1998
242
(continued)
Description
Run all test(s) except those identified by menu entry number (#) in the
command line.
Displays selected properties of the device(s) identified by menu entry
number (#) in the command line. The exact information provided varies
according to device type.
Setting
Description
No tests are run at power up.
off
Performs minimal testing of core
min
functionality.
Performs functional tests for all
med
system functions.
Runs exhaustive tests for all
max
functions except external
loopbacks. External loopback tests
are run only if diag-targets is
set to loopback, loopback3,
device&loopback, or
device&loopback,3.
Stops testing within a test routine
false
and prints a message as soon as an
error is detected. OBDiag then
skips to the next test routine in the
sequence.
Default
min
false