2.5 Sound Signalization

All ECLIPSE Series Keyboards have sound signalization for occurring of different system
events. The sound signalization has 4 volume levels adjustable at address 90 from the
Manager programming menus.
Sound Signal
Button
Confirmation
Cancel operation
Entry time
Exit time
Technical
problem
Chime
Fire alarm

2.6 Directions for Operation with LED Keyboards

LED 8, LED16 and LED32 are keyboards for management and programming with LED
displays. LED 8 shows information about 8 zones and manages 1 area. The display of
LED16 shows information about the first 16 zones and 2 areas of the systems, while the
display of LED32 shows information about all 32 zones and 8 areas of the system.
The entrance of codes, addresses, and data is done via the digit buttons. For the different
arming modes fast buttons with the respective symbol are used.

2.6.1 Special indication used in LED 8 keyboard

LED
Indication
Red
Red
Red
Green
(
*)
Off
Not used in manager and user programming menus.
* Used in the previous design of the keyboard as the button has the same functionality.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual
Description
Single short beep indicating the pressing of a key.
Two long sound signals, indicating the system confirmation to
executed operation.
A single long beep, indicating system incorrectly executed operation.
Continuous beep, indicating intrusion into an entrance zone.
Short beeps, indicating the system is armed and the user is required
to leave the entrance zone. Ten seconds before the exit time is over
beep frequency increases.
Two short beeps at every 20 sec, indicating a technical trouble. To
stop the signalization - press the TROUBLE button.
Short beeps with subsequently increasing period, indicating intrusion
into a zone with an activated chime option.
Three sound signals in sequence repeated every 5 seconds. That
kind of signalization shows activated fire detector in the premises.
Description
The system is in manager or user programming mode.
[O] is short from OPERATION – in programming mode.
[V] is short from VALUE – in programming mode.
The system is disarmed; normal operation mode.
The system is armed or the system is not ready to be armed.