ELECTRICAL SYSTEM
Generator inspection
A: Set the meter to the "Impedance" scale and take measurement at 2-way
connector to check pick-up. Reading should be: 100 Ohm (+/- 20%) at 20°C
B: Set the meter to the "Impedance" scale and check battery charging. Any
and all combinations of the three wires should give the following reading: 0.21
Ohm (+/- 15%) at 20 °C
C: Check that NONE of the three wires has continuity to ground.
At each engine overhaul, clean flywheel rotor to remove any debris
suspended in swirling oil and captured by the magnets.
M.12