Inverter Door (Door F) Open Interlock Switch
The Inverter Door Open Interlock Switch detects when the Inverter Door (F) is open.
To remove the switch:
1.
Remove the Inverter and base unit from the Finisher (page 5-5).
2.
Remove the Inverter Rear Covers (page 5-19).
3.
Remove the Top Cover (page 5-23).
4.
Disconnect the 2-wire cable from the connector (SNSCN2) at the Inverter
Controller Board.
5.
Free the cable from the cable harness.
6.
Remove a single small metal screw (metal, 4 mm) and remove the switch.
Service Parts Disassembly
Door Open
Interlock Switch
s7400-496
5-101