Staple/Fold Drive Unit
Note
The references indicate the connector on the Finisher Controller Board.
1.
Remove the Front Door (page 5-8) and slide out the Stapler Unit to the front.
2.
Remove the Rear Cover (page 5-11).
3.
Remove the screw (metal flange, 6 mm) and detach the Interface Retainer.
4.
Free the seven harness retainers, and disconnect the cable to connector CN18.
5.
Free the harness from the harness retainer and the Edge Saddle, disconnect the
two remaining cables to connector CN11 and CN7 and unroute from the harness.
Harness Retainers
5-30
Edge Saddle
Harness Retainer
Interface Retainer
Phaser 7400 Color Printer Options Service Manual
Harness Retainers
s7400-226