Rep 6.5 Drum Temperature Sensor; Rep 6.6 Front Door And Exit Door Interlock Switches - Xerox ColorQube 8570 Service Manual

Hide thumbs Also See for ColorQube 8570:
Table of Contents

Advertisement

REP 6.5 Drum Temperature Sensor

Parts List on
PL 6.1 Item 5
Removal
1.
Remove the Control Panel Cover
(REP
2.
Remove the Right Side Cover
(REP
3.
Remove the Left Side Cover
(REP
4.
Remove the Exit Cover
(REP
1.7).
5.
Remove the Ink Loader
(REP
1.8).
6.
Remove the Exit Module
(REP
3.13).
7.
Remove 1 screw that secures the Sensor to the Drum.
8.
Remove the Drum Temperature Sensor.
Figure 1 Removing the Drum Temperature Sensor
Repairs and Adjustments
REP 6.5, REP 6.6
1.5).
1.11).
1.10).

REP 6.6 Front Door and Exit Door Interlock Switches

Parts List on
PL 6.1 Item 6
Removal
1.
Remove the Control Panel Cover
2.
Remove the Control Panel
NOTE: Removal of the Outer Duplex Guide is not required to replace the Front Door
Interlock Switch.
3.
Remove the Left Side Cover
4.
Remove the Right Side Cover
5.
Remove the Outer Duplex Guide
6.
Disconnect the wiring harness connector P/J116.
7.
Remove the defective switch from the Outer Duplex Guide.
Figure 1 Removing the Exit Door and Front Door Switches
October 2012
4-100
(REP
1.5).
(REP
1.6).
(REP
1.10).
(REP
1.11).
(REP
3.4).