Compatibility RS232 interface / USB converter
[9.C]
System
Manufacturer
Ergospirometry
JAEGER/Viasys/Cardinal
Ergospirometry
Mijnhardt/Viasys/Cardinal
Ergospirometry
Cosmed / IT
Ergospirometry
CORTEX / DE
Ergospirometry
SensorMedics / US
Ergospirometry
SensorMedics / US
Ergospirometry
ZAN / DE
Ergospirometry
Ganshorn DE
Ergospirometry
MES PL
Ergospirometry
MedGraphics
Ergospirometry
Brainware
Ergospirometry
Innovision
Ergospirometry
Physio-Dyne
PC – ECG
JAEGER Viasys/Cardinal
PC – ECG
custoMed / DE
PC – ECG
custoMed / DE
PC – ECG
CardioControl WelchAlly
PC – ECG
Norav Medical
PC – ECG
Cosmed / IT
PC – ECG
PBI Pulse Biomedical
PC – ECG
Marquette/HELLIGE / GE
PC – ECG
Marquette/HELLIGE / GE
PC – ECG
Marquette/HELLIGE / GE
PC – ECG
Marquette/HELLIGE / GE
PC – ECG
OXFORD Instruments
PC – ECG
Delmar Reynolds
PC – ECG
Delmar Reynolds
PC – ECG
Dr. Vetter / DE
PC – ECG
Mesa Medizintechnik GmbH
ECG
Marquette/HELLIGE / GE
ECG
Marquette/HELLIGE / GE
ECG
ergoline / DE
ECG
SCHILLER CH
ECG
SCHILLER CH
ECG
Marquette / USA
ECG
ESAOTE / IT
Cardiac Rehabilitation
CORTEX / DE
Cardiac Rehabilitation
ergoline
Cardiac Rehabilitation
CogniMed
Cardiac Rehabilitation
CogniMed
Cardiac Rehabilitation
CogniMed
EMG
biovision
Blood pressure
SunTech Medical
robotic treadmill trainer Hocoma
PC Software
HUR / FI
PC Software
h/p/cosmos
PC Software
h/p/cosmos
PC Software
h/p/cosmos
PC Software
h/p/cosmos
PC Software
h/p/cosmos
PC Software
FitCentric
PC Software
ergoline
PC Software
FREI
PC-Software
MedTronic
PC-Software
simi
PC-Software
simi
PC-Software
Proxomed
Printer
HP Hewlett-Packard
RS232 Test plug
h/p/cosmos
Accessory equipment connected to the analog and digital interfaces must be certified according to the respective IEC standards, e.g. IEC 950 for data
processing equipment and IEC 601-1 for medical equipment. Furthermore all configurations shall comply with the valid version of the system standard IEC
601-1-1. Always use IEC 601-1 approved potential isolation components when linking medical devices via interface. It is not allowed to connect for instance
ECG-systems to sports running machines. Everybody who connects additional equipment to the signal input pert or signal output part configures a medical
system, and is therefore responsible that the system complies with the requirements of the valid version of the system standard IEC 601-1-1. (MDD: 13.6.c,
IEC 601-1: 6.8.2.c, 19.2.b, 19.2.c). More recent computers will have only an USB interface instead of the RS232 interface. For that case an „USB to RS232
interface-adapter-cable" is available at h/p/cosmos under item no. cos12769. To control via USB interface you need a processor Pentium 1.8 GHz or higher.
© 2008 h/p/cosmos sports & medical gmbh
Type
OXYCON
OXYCON
K 4 b² / Quark b² Quark PFT
MetaMax, MetaLyzer
via ECG
via ECG
ZAN 600
PowerCube
Start 2000
CPX
Innocor
as of version 5.01
MAX 1 / MAX 2
MasterScreen
Custo card
custo card m
Cardio Perfect
1200B & 1200S
Cardiovis / PLUS
QRS Card
CardioSoft
CardioSoft
CardioSys
CardioSys
Medilog QRS Card
CardioNavigator
CardioNavigator
PC ECG plus / ultra
CARDIAX PC-EKG
CardioSmart
CardioSmart
EK 3012 / DOS
AT 10 / AT 60
CS 100 / CS 200
MAX 1
CMS
ERS-System
Therapy monitor TM2
TM cardio 1000 & 2000
TM sport 1000 & 2000
Tango
Lokomat/Lokocontrol
Treadmill-Trainer
h/p/cosmos para graphics DOS
h/p/cosmos para graphics
h/p/cosmos para control
h/p/cosmos para analysis
h/p/cosmos para motion
NetAthlon
OPTICARE
Chip-Ei
Lactware as of version 4.3
simi motion twin
simi motion as of version 8.0
Kardiowell-System (chip card)
PCL code
LED + switch
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
email@h-p-cosmos.com
RS 232 interface protocol
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
Trackmaster in km/h
HELLIGE/Trackmaster
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
Trackmaster in km/h
h/p/cosmos coscom
custo card
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
Trackmaster in km/h
Trackmaster in mph
Trackmaster in km/h
Trackmaster in mph
h/p/cosmos coscom
Trackmaster in km/h
as of version 2.403
Trackmaster in mph
as of version 2.403
Trackmaster in km/h
h/p/cosmos coscom
Trackmaster in km/h
Trackmaster in mph
custo card
SCHILLER (Pacer)
Trackmaster in km/h
Marquette
Trackmaster in km/h
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
> version 4.32
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
as of Version4.31
h/p/cosmos coscom
h/p/cosmos cosrec
h/p/cosmos coscom
®
®
h/p/cosmos coscom
®
2.0 pro
h/p/cosmos coscom
®
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
h/p/cosmos coscom
Printer protocol
h/p/cosmos Loop-Back
created 01.09.2008
printed 08.10.2008
technical data
Setup running machine
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
©
LN
page: 134 of 176