[7.D3] Devices Without Userterminal And Without Automatic Oil-Pump - h/p/cosmos 150/50 locomotion de med Operating Instructions And Service Manual

Hide thumbs Also See for 150/50 locomotion de med:
Table of Contents

Advertisement

[03]
[7.D2]
After all required steps have been performed the tissues need to be returned to h/p/cosmos for further
[04]
evaluation. The tissues will be weighed again and according to the weight difference h/p/cosmos can
calculate if a modification of the lubrication interval is necessary.
Devices without UserTerminal and without automatic oil-pump
[7.D3]
The devices without UserTerminal are equipped with an automatic oil message via acoustic signal (bleep)
indicating the device needs to be lubricated. On standard setting every 1000 km (special device might have
different intervals) after switching on the device (main power switch) the acoustic signal "5 times LONG (code for
"0")" and 1 time SHORT + 4 times LONG (code for "1") will be repeated 3 times. The device has no sensor and the
oil message will not terminate automatically after lubrication.
The lubrication of the running belt and running surface is done with the enclosed, to the extent of delivery,
accessories (bottle of lubricant and 10ml syringe). Use the provided lubricant only. Other available oils and
lubricants can damage the running belt and running surface and therefore lead to a breakdown of the running
machine.
Please contact h/p/cosmos to receive the special oil. The running belt should be lubricated after 1000 km (special
devices might have different intervals) at the latest or/and after hearing dry grinding noises during operation. After
lubrication the oil message has to be terminated with "OPTION 01". An external UserTerminal or a PC-software
h/p/cosmos para control
© 2008 h/p/cosmos sports & medical gmbh
®
is required for this.
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
email@h-p-cosmos.com
maintenance & safety inspections
1. Take the tissue out of the plastic bag and
place it directly to the previously marked
position under the running belt.
2. Press with your hand on the running belt
above the tissue and move the running
belt together with the tissue for exact 1
meter.
3. Take out the tissue and put it into the
corresponding plastic bag. Take care that
the plastic bag is closed sufficiently.
Repeat steps 1 to 3 for the remaining
positions.
created 01.09.2008
printed 08.10.2008
page: 107 of 176