h/p/cosmos 150/50 locomotion de med Operating Instructions And Service Manual page 109

Hide thumbs Also See for 150/50 locomotion de med:
Table of Contents

Advertisement

maintenance & safety inspections
running, cycling, cross-country, skating
[inline, roller ski]
Valve-cock position [1] horizontally: The distributor [2] is
adjusted for lubrication [3] only in the center of the running-
deck [4].
The valve-cock position only changes the distribution of the
oil amount to the various oil-outlets (tubes).
The total oil-supply amount of the oil-pump always remains
constant, independent from the valve-cock position.
A nearly empty oil-tank will be indicated by the control lamp
"Empty Oil-tank" at the external control unit. Refill the oil-
tank when control lamp indicates
wheelchair
Valve-cock position [1] vertically: The distributor [2] is
adjusted for lubrication [3] over the entire width of the
running-deck [4].
The valve-cock position only changes the distribution of the
oil amount to the various oil-outlets (tubes). The total oil-
supply amount of the oil-pump always remains constant,
independent from the valve-cock position.
A nearly empty oil-tank will be indicated by the control lamp
"empty oil-tank" at the external control unit. Refill the oil-
tank when control lamp indicates. Additionally at standard
settings the word "OIL" will flash every 1000 km at the
display. If this message occurs, check the oil-level in the oil-
tank and refill preterm if necessary.
The device does not have a sensor, the oil-message does not extinguish automatically. After checking the oil-level,
the message has to be quit with „OPTION 01".
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
© 2008 h/p/cosmos sports & medical gmbh
email@h-p-cosmos.com
created 01.09.2008
printed 08.10.2008
page: 109 of 176

Advertisement

Table of Contents
loading

This manual is also suitable for:

MercuryQuasarPulsarStellarStratosVenus ... Show all

Table of Contents