[10.L] Running Belt Rotation Reversible For Downhill Walk; [10.L1] Ripcord With Magnet Switch; [10.L2] Change From Forward To Reverse Rotation - h/p/cosmos 150/50 locomotion de med Operating Instructions And Service Manual

Hide thumbs Also See for 150/50 locomotion de med:
Table of Contents

Advertisement

Running belt rotation reversible for downhill walk
[10.L]
N
As the subject is running against the usual running belt rotation and therefore has no control
of the UserTerminal it is necessary to have a supervisor who controls the running machine
during the training. For safety reasons the max. speed has been limited with the models
possessing a cross-bar handrail or a motor case cover. Use a safety arch with harness for
additional safety.
N
Turn the key-operated switch for the reverse belt rotation only when the running belt is not
moving.
The function running belt rotation reverse (optional) permits a simulation of a downhill run. To prevent any abuse, the
function can only be activated by a key-operated switch (on the external UserTerminal of the oversize running machine
by rotary switch).
N
If the key-operated switch is being activated at stand still, the running belt rotation reverse will be in function at the
next start.
N
If the key-operated switch is being activated while the Running-Machine is in operation, the Running-Machine stops
and the running belt rotation reverse will be in function at the next start.
The running belt rotation reverse will be announced by an acoustic signal and the display = "r." Speed will be
indicated as a negative value while in operation = „-0.0 ... -5.0".
Ripcord with magnet switch
[10.L1]
The emergency-stop with magnetic switch is
a safety feature that is used especially with
reverse belt rotation (downhill). The athlete
or patient is connected to the magnetic
switch at the UserTerminal via a ripcord at
the waist belt.
In case of an emergency the magnet gets
ripped of from the UserTerminal and the
running machine stops immediately. The
ripcord is not a prevention of falling. At
removed magnet „PULL STOP" will occur in
the display.
Ripcord with magnet switch [cos00098050043]
Change from forward to reverse rotation
[10.L2]
N
Turn the key-operated switch and start the machine without a subject on the running belt only when the belt is
not moving.
N
Observe the belt position for 2 minutes and correct the belt position with the belt adjustment screw (see
chapter maintenance and belt adjustment). It is normal, that after changing the belt rotation, the belt will move
to one side and therefore the running belt needs to be readjusted to the center of the running track.
N
Once the belt is readjusted, STOP the belt and operate the machine with the subject on the belt.
© 2008 h/p/cosmos sports & medical gmbh
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
email@h-p-cosmos.com
accessories & options
created 01.09.2008
printed 08.10.2008
page: 148 of 176

Advertisement

Table of Contents
loading

This manual is also suitable for:

MercuryQuasarPulsarStellarStratosVenus ... Show all

Table of Contents