E20
Elevation system
[8.I1]
exceeded the max. value
E21
Error of elevation system
E30
Error of
speed / distance measurement
© 2008 h/p/cosmos sports & medical gmbh
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
email@h-p-cosmos.com
=
!
„E 20"
„ELEV" flashing
§ $ %
„HELP" flashing
Running machine is still functioning (except for the lift device)
N
Lifting element exceeded the maximum value. The combined
0% / maximum % -contact had been activated
N
Incorrect measurement of angle of elevation
N
Maybe wrong adjusted, dirty or defective elevation sensor
N
Contact authorized service engineer
=
!
„E 21"
„ELEV" flashing
§ $ %
„HELP" flashing
Running machine is still functioning (except for the lift device)
N
Maybe technical blocking of elevation (e.g. overload)
N
Maybe power supply too weak because of an extension cable
etc.
N
Check power supply and power cord
N
Maybe elevation sensor adjustment is wrong or the sensor is
dirty or defective
N
Contact authorized service engineer
=
!
„E 30"
„INCR" flashing
§ $ %
„HELP" flashing
Running machine can still operate for a few seconds at speed of
max. approx. 1 km/h
N
Maybe technical blocking of running belt (e.g. alien element,
towel trapped in device)
N
Maybe power supply too weak because of an extension cable,
etc.
N
Check power supply and power cord
N
Maybe speed sensor adjustment is wrong, the sensor may be
dirty or defective or the speed calibration is wrong. OPTION 34
N
Safety delay time (inverter or MCU) is longer than the high
acceleration command (SPRINT function or high acceleration
level)
N
Trouble shooting see Administrator OPTION 48
N
Contact authorized service engineer
N
Check voltage supply. Do not use extension cords. Connect
the machine direct to the socket in the wall
N
Check mechanical parts for any malfunction. Maybe several
persons were standing on the machine for a moment?
N
Remove pleated bellow from upper frame (where applicable,
depending on frame).
N
Attention: Dangerous voltage and danger of being hurt when
the device is open. Do not touch the parts inside the device
created 01.09.2008
printed 08.10.2008