[9.B] Emc Electromagnetic Compatibility. Guidance And Manufacturer's Declaration - h/p/cosmos 150/50 locomotion de med Operating Instructions And Service Manual

Hide thumbs Also See for 150/50 locomotion de med:
Table of Contents

Advertisement

EMC electromagnetic compatibility. Guidance and manufacturer's declaration
[9.B]
Table 201: Guidance and manufacturer's declaration - electromagnetic emissions (for all equipment and systems)
The running machine is intended for use in the electromagnetic environment specified below. The customer or the user of the running machine should
assure that it is used in such an environment.
Emissions test
RF emissions CISPR11
RF emissions CISPR11
Harmonic emissions IEC 61000-3-2
Voltage fluctuations/ flicker emissions
IEC 61000-3-3
Table 202: Guidance and manufacturer's declaration - electromagnetic immunity (for all equipment and systems)
The running machine is intended for use in the electromagnetic environment specified below. The customer or the user of the running machine should
assure that it is used in such an environment.
Immunity test
Electrostatic discharge (ESD)
IEC 61000-4-2
Electrical fast transient/burst
IEC 61000-4-4
Surge
IEC 61000-4-5
Voltage dips,
short interruptions and
voltage variations on
power supply input lines
IEC 61000-4-11
Power
frequency
(50/60
magnetic field
IEC 61000-4-8
NOTE U
is the A.C. mains voltage prior to application of the test level.
T
Please pay special attention also to the other EMC related chapters of this manual:
a)
Chapter: Safety, Installation, Operation, POLAR heart rate monitor: EMC
b)
Chapter: Error, Malfunction, possible interference
© 2008 h/p/cosmos sports & medical gmbh
Compliance
Group 1 Class B
Group 1 Class B
Class A
Complies
IEC 60601 test level
±6 kV contact
±8 kV air
±2 kV for power supply lines
±1 kV for input/output lines
±1 kV differential mode
±2 kV common mode
<5 % U
T
(>95 % dip in U
)
T
for 0.5 cycle
40 % U
T
(60 % dip in U
)
T
for 5 cycles
70 % U
T
(30 % dip in U
)
T
for 25 cycles
<5 % U
T
(>95 % dip in U
)
T
for 5 sec
Hz)
3 A/m
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
email@h-p-cosmos.com
Electromagnetic environment — guidance
The running machine uses RF energy only for its internal function. Therefore, its RF
emissions are low and are not very likely to cause any interference in nearby
electronic equipment.
The running machine is suitable for use in all establishments including domestic
and those directly connected to the public low-voltage power supply network that
supplies buildings used for domestic purposes.
Compliance level
±6 kV contact
±8 kV air
±2 kV for power supply lines
±1 kV for input/output lines
±1 kV differential mode
±2 kV common mode
<5 % U
T
(>95 % dip in U
)
T
for 0.5 cycle
40 % U
T
(60 % dip in U
)
T
for 5 cycles
70 % U
T
(30 % dip in U
)
T
for 25 cycles
<5 % U
T
(>95 % dip in U
)
T
for 5 sec
Not applicable
created 01.09.2008
printed 08.10.2008
technical data
Electromagnetic environment - guidance
Floors should be wood, concrete or ceramic tile. If
floors are covered with synthetic material, the
relative humidity should be at least 30 %.
Mains power quality should be that of a typical
commercial or hospital environment.
Mains power quality should be that of a typical
commercial or hospital environment.
Mains power quality should be that of a typical
commercial or hospital environment. If the user of
the
running
machine
requires
Operation during power mains interruptions, it is
recommended that the running machine be
powered from an uninterruptible power supply or
a battery. Caution! running machines require high
capacity UPS because of high capacity motor
drive.
Power frequency magnetic fields should be at
levels characteristic of a typical location in a
typical commercial or hospital environment.