h/p/cosmos 150/50 locomotion de med Operating Instructions And Service Manual page 131

Hide thumbs Also See for 150/50 locomotion de med:
Table of Contents

Advertisement

Dimension frame
length x width x height
Track access height from floor
(optional installation in pit)
Weight of device
Weight load limits to floors
(traffic load to DIN 1055 part 3)
Max. permissible user weight on
running surface
Environmental conditions:
Transport and storage
Environmental conditions:
Operation
Central lubrication system
Store program space
RS232 Digital interface / serial port
Heart rate measurement and heart
rate dependent endurance control
(target pulse programming)
PC software
Reverse belt rotation / downhill
Safety arch with harness***
Wheel chair stabilizer
Monitor arm and laptop computer
* Overload and weak power supply (undervoltage) could lead to higher discrepancies concerning the speed-display or dripping of the fuse. ** The time of
operation of the elevation motor (TO = 15 %) converts to approx. 5 full elevation cycles. Overload can result in temporary tripping of the fuse, but can be
used again after short cool down period. Treadmills of the h/p/cosmos saturn series built approx. before January 2007 have a maximum elevation of 25%.
*** For maximum stress tests and with oversize running machines (track sizes) a safety facility (e.g. a safety harness with chest belt) is necessary and highly
recommended. When using a front-bar handrail (crossbar), the speed is limited to 5 km/h for safety reasons. Data of weight and measurements can deviate.
Ask for further details and optional equipment or visit www.h-p-cosmos.com. Subject to technical alterations without prior notice. E & OE.
© 2008 h/p/cosmos sports & medical gmbh
2400 x1150 x 1380
2900 x1150 x 1380
[a]
[b]
2400 x 1400 x
2900 x 1400 x 1380
1380
[c]
2900 x 1650 x 1380
480 mm
480 mm
800 kg
1000 kg
[a] 1000 kg
[b] 1100 kg
[c] 1200 kg
9.20 kN/m²
In case of any further questions related to load limits onto floors, please ask our service department.
temperature: –30...+50 °C
humidity: 0...95% - without condensation
barometric pressure: 700...1060hPa
temperature: +10...+40 °C (deviation on request)
humidity: 30...70% - without condensation (up to 95% on request)
barometric pressure: 700...1060hPa
Maximum operating altitude: approx. 10,000 feet (3000m), without pressurization
manual / running machines with [r] have automatic central lubrication system
6 training profiles / 10 test profiles / 8 user defined profiles
COM1: standard; COM2: standard; COM3: optional (standard for service); COM4: optional
(model h/p/cosmos venus 4.0: 3 channel receiver, ECG precisely)
h/p/cosmos para control 4.0
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
email@h-p-cosmos.com
3400 x1150
3400 x1650 x 1380
x 1380
[e]
[d]
on request.
3400 x1400
depends on
x 1380
installation
480 mm
480 mm
[e] on request.
1100 kg
1400 kg
[d] 1200 kg
[e] on request
5.00 bis 6.00 kN/m² depends on model
280 kg
(deviation on request specially made)
6-channel receiver, ECG precisely
connection for external heart rate receiver
and h/p/cosmos para graphics
®
option: h/p/cosmos para analysis
standard
option
option
option
created 01.09.2008
printed 08.10.2008
technical data
on request
[f]
on request.
depends on installation
on request
on request.
depends on installation
on request
included
®
®
page: 131 of 176

Advertisement

Table of Contents
loading

This manual is also suitable for:

MercuryQuasarPulsarStellarStratosVenus ... Show all