EMC Electromagnetic Compatibility
[3.G4]
The running-machines for the professional application in sports and fitness (with c mark) have been built
corresponding to the European Union Council Directive 89/336/EEC (EMC) and the low voltage directive
73/23/EEC. Norms: EMC: EN55011; EN61000-6-1; EN61000-3-2; EN61000-3-3, Safety: EN60950
The running-machines for medical applications (with n mark) have been built corresponding to the
European Union Council Directive 93/42/EEC
Norms: EMC: EN60601-1-2; EN61000-3-2; EN61000-3-3, Safety: EN60601-1
Certification bodies: Mitsubishi Electric Europe / EMC-Laboratroy, Mündelheimer Weg 35, DE 40472 Düsseldorf
EMV Testhaus GmbH, Gustav - Hertz - Strasse 35, DE 94315 Straubing / Germany, J. Schmitz GmbH, 83022
Rosenheim
Strong electromagnetic fields, transmitters and interferences, which are above the normal tolerance, can interfere
with measuring fuctions and displays of the running machines and can lead to other malfunctions.
Follow details to EMC values, guidance and manufacturers declaration in this manual in chapter „technical data"
General advice
[3.G5]
The device is assigned to overvoltage-category II and pollution level I.
Fields of application / intended use
[3.H]
All running-machines are built corresponding to the classes S and A based on EN 957-1:2005 / EN 957-6:2001.
Professional application in sports and fitness
[3.H1]
The running machine models designed for sports and fitness have not been tested for application in medical areas
and therefore are not qualified for that field of application. They must not be connected to other medical devices.
You can apply these models in endurance training walking and running.
Professional application in the medical field
[3.H2]
The running machine models designed for professional application in the medical field are also qualified for sports
and fitness use as well as for application in the medical field.
N
Endurance training walking and running
N
Endurance tests and EMG-measuring with the subject in the laboratory (only with safety arch / fall stop)
N
Ergometry on the Running-Machine, Exercise- ECG and Ergospirometrie (only with safety arch / fall stop)
N
Gait training
N
Recreational fitness training
Children are only allowed to use the running machine under constant supervision of a
medical doctor and only when safeguarded by safety harness with fall-stop. Additionally
h/p/cosmos suggests the use of adjustable handrails.
© 2008 h/p/cosmos sports & medical gmbh
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
email@h-p-cosmos.com
safety, warnings, precautions, prohibitions
created 01.09.2008
printed 08.10.2008
page: 17 of 176