[6.B1]
OP35
Oil Interval
© 2008 h/p/cosmos sports & medical gmbh
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
email@h-p-cosmos.com
N
Running machine series h/p/cosmos quasar with
special speed 45 km/h:
Speed Calibration Value: 2.874
Inverter Frequency:
N
Running machine series h/p/cosmos pulsar 3p with 40 km/h:
Speed Calibration Value: 2.874
Inverter Frequency:
N
Running machine series h/p/cosmos pulsar 3p with
special speed 45 km/h:
Speed Calibration Value: 2.874
Inverter Frequency:
The distance interval for indication of "OIL" service required can be
adjusted by means of option 35.
Standard = 1000 km for treadmills, 100 km for ladder-ergometers. OIL
intervals are indicated with error code "E01" "OIL" every 1000 km.
§
reports: oil interval in km (Standard = 1.000)
~
km is flashing
Adjustment range: OFF, 100 ... 5.000 km
Do not change the interval without prior communication with
h/p/cosmos. For the models h/p/cosmos venus, saturn und orbiter,
JAEGER LE 580 and bigger as well as COSMED T200 and bigger
option number 35 is not adjustable, as the machines are equipped with
an automatic oil pump and a tank.
created 01.09.2008
printed 08.10.2008
optional settings
125 Hz
110 Hz
125 Hz
page: 88 of 176