h/p/cosmos 150/50 locomotion de med Operating Instructions And Service Manual page 126

Hide thumbs Also See for 150/50 locomotion de med:
Table of Contents

Advertisement

E90
Error chip-card-drive
[8.I1]
(not all models)
E91
Error chip-card-drive
(not all models)
E92
Error chip-card-drive
(not all models)
E93
Error chip-card-drive
(not all models)
© 2008 h/p/cosmos sports & medical gmbh
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
email@h-p-cosmos.com
=
„E90"
§ $ %
„HELP" flashing.
Running machine is still functioning (except chip card function)
N
Communication malfunction with Chip-Card
N
Insert chip-card to the chip-card-drive
N
Replace chip-card
N
Replace chip-card-drive
N
Contact authorized service engineer
=
„E91"
§ $ %
„HELP" flashing.
Running machine is still functioning (except chip card function)
N
Client number at START and STOP not identical.
N
Check chip-card
N
Insert the correct Chip-Card
=
„E92"
§ $ %
„HELP" flashing.
Running machine is still functioning (except chip card function)
N
Too many training weeks
N
Check period of training
N
Check system date and time settings of the running machine
N
Re-program chip-card
=
„E93"
§ $ %
„HELP" flashing.
Running machine is still functioning (except chip card function)
N
Test ident on the chip-card not accepted
N
False chip-card in the chip-card-drive
N
Insert the correct chip-card
created 01.09.2008