Devices for Sports and Fitness manufacturing before manufacturing date 12/2007
The running machine can be switched on directly at the expulsion fuse at the FrontTerminal (frontal section below
the hood) to the condition "stand-by mode" (if the emergency-stop has been activated a flashing notice „PULL
STOP" appears on the display.).
Expulsion fuse and
main switch 2- or 3-pole
Switching the device off
[4.D3]
N
The ON-/OFF-intervals must not be shorter than 1-2 minutes (at models with 3-phase
connection: 2-3 minutes). Otherwise it could lead to interference in the adjustment of
the motor or to the failure of the backup.
N
The models for medical application with the isolation transformer have an inrush-
current limiter (surge guard). Too short switch on / switch off intervals will lead to a
deactivation of the inrush current limiter and results in an overload of the circuit fuse.
N
For the professional use, where the devices are often being used daily, we recommend
to switch on the devices in the morning, and leave it in the stand-by mode during the
day.
Switch off the running machine by pressing the black key (until 2003 red "O" key) at the UserTerminal (some
models at the front of the device). The indicator within the key is extinguished. At some models built before
12/2007 the location of the ON-/OFF-key could also be the UserTerminal.
Devices for Sports and Fitness manufacturing before 12/2007
The machine can be switched off directly with the explusion fuse at the FrontTerminal (frontal section below the
hood).
© 2008 h/p/cosmos sports & medical gmbh
ON / OFF button
with control lamp
file: n:\article\cos14310m5-v1.04hpc-en\20080901_cos14310m5-v1.04hpc-en_manual_h-p-cosmos_running_machine.doc
email@h-p-cosmos.com
installation & commissioning
ON / OFF button
Main switch from construction
until 2003
200...300/75...125cm onwards
created 01.09.2008
printed 08.10.2008
size running surface
page: 34 of 176