SIP User's Manual
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Status Changes:
Condition:
Alarm status:
<text value>:
Condition:
Alarm status:
<text value>:
Condition:
Alarm status:
Corrective Action:
Alarm:
OID:
Default Severity
Event Type:
Probable Cause:
Alarm Text:
Note:
Status Changes:
Condition:
Alarm status:
Condition:
Alarm status:
Corrective Action:
Version 5.0
Table I-9: acgwAdminStateChange Alarm Trap
acgwAdminStateChange
1.3.6.1.4.1.5003.9.10.1.21.2.0.7
Major
processingErrorAlarm
outOfService (71)
Network element admin state change alarm Gateway is <text>
Admin state changed to shutting down
Major
Shutting down. No time limit.
Admin state changed to locked
Major
Locked
Admin state changed to unlocked
Cleared
A network administrator has taken an action to lock the device. No corrective
action is required.
Table I-10: acOperationalStateChange Alarm Trap
acOperationalStateChange
1.3.6.1.4.1.5003.9.10.1.21.2.0.15
Major
processingErrorAlarm
outOfService (71)
Network element operational state change alarm. Operational state is disabled.
This alarm is raised if the operational state of the node goes to disabled. The
alarm is cleared when the operational state of the node goes to enabled. In IP
systems, the operational state of the node is disabled if the device fails to
properly initialize.
Operational state changed to disabled
Major
Operational state changed to enabled
Cleared
In IP systems, check for initialization errors. Look for other alarms and Syslogs
that might provide additional information about the error.
455
I. SNMP Traps
December 2006