11.3.2 Working with DMS-100 Switches

The DMS-100 switch requires the following NFAS Interface ID definitions:
InterfaceID #0 for the Primary trunk
InterfaceID #1 for the Backup trunk
InterfaceID #2 for a 24 B-channel T1 trunk
InterfaceID #3 for a 24 B-channel T1 trunk
Etc.
For example, if four T1 trunks on a gateway are configured as a single NFAS group, with
Primary and Backup T1 trunks, that is used with a DMS-100 switch, the following
parameters should be used:
NFASGroupNumber_0 = 1
NFASGroupNumber_1 = 1
NFASGroupNumber_2 = 1
NFASGroupNumber_3 = 1
DchConfig_0 = 0
DchConfig_1 = 1
DchConfig_2 = 2
DchConfig_3 = 2
If there is no NFAS Backup trunk, the following configuration should be used:
ISDNNFASInterfaceID_0 = 0
ISDNNFASInterfaceID_1 = 2
ISDNNFASInterfaceID_2 = 3
ISDNNFASInterfaceID_3 = 4
ISDNIBehavior = 512
;ISDNNFASInterfaceID coniguration above
NFASGroupNumber_0 = 1
NFASGroupNumber_1 = 1
NFASGroupNumber_2 = 1
NFASGroupNumber_3 = 1
DchConfig_0 = 0
DchConfig_1 = 2
DchConfig_2 = 2
DchConfig_3 = 2
11.4

Redirect Number and Calling Name (Display)

The following tables define the Mediant 1000 redirect number and calling name (Display)
support for various PRI variants:
NT TE
TE NT
NT TE
TE NT
SIP User's Manual
;Primary T1 trunk
;Backup T1 trunk
;B-Channel NFAS trunk
;B-channel NFAS trunk
;This parameter should be added because of
;Primary T1 trunk
;B-Channel NFAS trunk
;B-Channel NFAS trunk
;B-channel NFAS trunk

Table 11-1: Calling Name (Display)

DMS-100
NI-2
Yes
Yes

Table 11-2: Redirect Number

DMS-100
NI-2
Yes
Yes
318
4/5ESS
Yes
No
Yes
No
4/5ESS
Yes
Yes
Yes
Yes
Mediant 1000
Euro ISDN
Yes
No
Euro ISDN
Yes
No
Document #: LTRT-83301