Table 5-8: Supplementary Services Parameters (continues on pages 92 to 94)
Parameter
Beep
Waiting
Duration
[WaitingBeepDuration]
Enable Caller ID
[EnableCallerID]
Caller ID Type
[CallerIDType]
Hook-Flash Code
[HookFlashCode]
MWI Parameters
Enable MWI
[EnableMWI]
MWI Analog Lamp
[MWIAnalogLamp]
MWI Display
[MWIDisplay]
Version 5.0
Description
Duration (in msec) of waiting indications that are played to the receiving side of the
call (FXS only) for Call Waiting.
The default value is 300.
No [0] = Disable the Caller ID service (default).
Yes [1] = Enable the Caller ID service.
If the Caller ID service is enabled, then, for FXS modules, calling number and
Display text are sent to gateway port.
For FXO modules, the Caller ID signal is detected and is sent to IP in SIP INVITE
message (as 'Display' element).
For information on the Caller ID table, refer to Section
To disable/enable caller ID generation per port, refer to Section
124.
Defines one of the following standards for detection (FXO) and generation (FXS)
of Caller ID and detection (FXO) of MWI (when specified) signals.
Bellcore
[0] (Caller ID and MWI) (default).
ETSI
[1] (Caller ID and MWI)
NTT
[2]
Backward Compatible [3]
British
[4]
DTMF ETSI
[16]
Denmark
[17] (Caller ID and MWI)
India
[18]
Brazil
[19]
Note 1: The Caller ID signals are generated/detected between the first and the
second rings.
Note 2: To select the Bellcore Caller ID sub standard, use the parameter
'BellcoreCallerIDTypeOneSubStandard'. To select the ETSI Caller ID sub
standard, use the parameter 'ETSICallerIDTypeOneSubStandard'.
Note 3: To select the Bellcore MWI sub standard, use the parameter
'BellcoreVMWITypeOneStandard'. To select the ETSI MWI sub standard, use the
parameter 'ETSIVMWITypeOneStandard'.
Determines the digit pattern used by the PBX to indicate a 'Hook-Flash' event.
When this pattern is detected from the Tel side, the gateway responds as if a
Hook-Flash event occurs and sends an INFO message indicating 'Hook Flash'. If
configured and a Hook-Flash indication is received from the IP side, the gateway
generates this pattern to the Tel side.
The valid range is a 25-character string.
Enable MWI (message waiting indication).
Disable
[0] = Disabled (default).
Enable
[1] = MWI service is enabled.
This parameter is applicable only to FXS modules.
Note: The Mediant 1000 only supports reception of MWI.
For detailed information on MWI, refer to Section
Disable
[0] = Disable (default).
Enable
[1] = Enable visual Message Waiting Indication, supplies line voltage of
approximately 100 VDC to activate the phone's lamp.
This parameter is applicable only to FXS modules.
Disable
[0] = MWI information isn't sent to display (default).
Enable
[1] = MWI information is sent to display.
If enabled, the gateway generates an MWI FSK message that is displayed on the
MWI display.
This parameter is applicable only to FXS modules.