Table I-2: acBoardConfigurationError Alarm Trap

acBoardConfigurationError
1.3.6.1.4.1.5003.9.10.1.21.2.0.2
Critical
equipmentAlarm
underlyingResourceUnavailable (56)
Board Config Error: <text>
A configuration error was detected
critical
A run-time specific string describing the configuration error.
After configuration error
Status stays critical until reboot. A clear trap is not sent.
Inspect the run-time specific string to determine the nature of the configuration
error. Fix the configuration error using the appropriate tool: Web interface, EMS,
or ini file. Save the configuration and if necessary reset the device.
Table I-3: acBoardTemperatureAlarm Alarm Trap
acBoardTemperatureAlarm (doesn't apply to the TP-260 board)
1.3.6.1.4.1.5003.9.10.1.21.2.0.3
Critical
equipmentAlarm
temperatureUnacceptable (50)
Board temperature too high
Temperature is above 60 degrees C (140 degrees F)
Critical
After raise, temperature falls below 55 degrees C (131 degrees F)
Cleared
Inspect the system. Determine if all fans in the system are properly operating.