AudioCodes Mediant 1000 User Manual page 221

Sip media gateways
Hide thumbs Also See for Mediant 1000:
Table of Contents

Advertisement

SIP User's Manual
Table 6-2: System Parameters (continues on pages 220 to 225)
ini File Field Name
Web Parameter Name
EnableDiagnostics
WatchDogStatus
LifeLineType
GWAppDelayTime
ActivityListToLog
Version 5.0
Valid Range and Description
Checks the correct functionality of the different hardware components on the
gateway. On completion of the check, if the test fails, the gateway sends
information on the test results of each hardware component to the Syslog
server.
0 = Rapid and Enhanced self-test mode (default).
1 = Detailed self-test mode (full test of DSPs, PCM, Switch, LAN, PHY and
Flash).
2 = A quicker version of the Detailed self-test mode (full test of DSPs, PCM,
Switch, LAN, PHY, but partial test of Flash).
For detailed information, refer to Section
0 = Disable gateway's watch dog.
1 = Enable gateway's watch dog (default).
The Lifeline is activated on:
0 = Power down (default)
1 = Power down or when link is down (physical disconnect)
2 = Power down or when link is down or on network failure (logical link
disconnect)
Note: To enable Lifeline switching on network failure, LAN watch dog must be
activated (EnableLANWatchDog=1).
For a description of this parameter, refer to
The Activity Log mechanism enables the gateway to send log messages (to a
Syslog server) that report certain types of web actions according to a pre-
defined filter.
The following filters are available:
PVC (Parameters Value Change) - Changes made on-the-fly to parameters.
AFL (Auxiliary Files Loading) - Loading of auxiliary files (e.g., via Certificate
screen).
DR (Device Reset) - Device reset via the Maintenance screen.
FB (Flash Memory Burning) - Burning of files / parameters to flash (e.g.,
Maintenance screen).
SWU (Device Software Update) - cmp loading via the Software Upgrade
Wizard.
ARD (Access to Restricted Domains) - Access to Restricted Domains.
The following screens are restricted:
(1) ini parameters (AdminPage)
(2) General Security Settings
(3) Configuration File
(4) IPSec/IKE tables
(5) Software Upgrade Key
(6) Internal Firewall
(7) Web Access List.
(8) Web User Accounts
NAA (Non Authorized Access) - Attempt to access the Embedded Web Server
with a false / empty username or password.
SPC (Sensitive Parameters Value Change) - Changes made to sensitive
parameters:
(1) IP Address
(2) Subnet Mask
(3) Default Gateway IP Address
(4) ActivityListToLog
For example:
ActivityListToLog = 'pvc', 'afl', 'dr', 'fb', 'swu', 'ard', 'naa', 'spc'
221
6. ini File Configuration of the Mediant 1000
15.1
on page 365.
Table 5-7
on page 85.
December 2006

Advertisement

Table of Contents
loading