Troubleshooting An Unsuccessful Loading Of A Key; Abort Procedure - AudioCodes Mediant 1000 User Manual

Sip media gateways
Hide thumbs Also See for Mediant 1000:
Table of Contents

Advertisement

SIP User's Manual

12.7.6 Troubleshooting an Unsuccessful Loading of a Key

If the Syslog server indicates that a Software Upgrade Key file was unsuccessfully loaded
(the SN_ line is blank), take the following preliminary actions to troubleshoot the issue:
Open the Software Upgrade Key file and check that the S/N line of the specific device
whose key you want to update is listed in it. If it isn't, contact AudioCodes.
Verify that you've loaded the correct file and that you haven't loaded the device's ini
file or the CPT ini file by mistake. Open the file and ensure that the first line is
[LicenseKeys].
Verify that you didn't alter in any way the contents of the file.

12.7.7 Abort Procedure

Reload the key you backed-up in Section
capabilities to what they originally. To load the backed-up key use the procedure described
in Section
12.7.2
Version 5.0
on page 334.
337
12. Advanced System Capabilities
12.7.1
on page
334
to restore your device