Microscan QX Hawk User Manual page 251

Industrial imager
Hide thumbs Also See for QX Hawk:
Table of Contents

Advertisement

Sequence on No Read
Sequence on No Read is useful when the imager needs to stay in sequence even if no
decode occurs.
When Sequence on No Read is Enabled and
the imager sequences the master symbol on every match or No Read. When disabled, it
does not sequence on a No Read.
Consider the following decodes as an example of Sequence on No Read Enabled:
Master Symbol
001
002
003
004
005
006
007
Consider the following decodes as an example of Sequence on No Read Disabled:
Master Symbol
001
002
003
003
004
004
004
QX Hawk Industrial Imager User's Manual
Decoded Symbol
001
002
No Read
004
No Read
No Read
007
Decoded Symbol
001
002
No Read
003
No Read
No Read
004
Matchcode Type
is set to Sequential,
Master Symbol after Decode
002
003
004 (sequence on No Read)
005
006 (sequence on No Read)
007 (sequence on No Read)
008
Master Symbol after Decode
002
003
003 (not sequenced)
004
004 (not sequenced)
004 (not sequenced)
005
Parameters
5-167

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QX Hawk and is the answer not in the manual?

Questions and answers

Table of Contents