Command Notes (Pulse Current Measurements) - Keithley 2302 Instruction Manual

Battery/charger simulator
Hide thumbs Also See for 2302:
Table of Contents

Advertisement

Table 3-2
SCPI commands — pulse current measurements (cont.)
Command
SENSe[1]
:PCURrent
:FAST
:SEARch
:DETect
:TimeOUT
SENSe2
:FUNCtion "PCURrent"
:PCURrent
:AVERage <NRf>
:MODE <name>
:TIME
:AUTO
:HIGH <NRf>
:LOW <NRf>
:AVERage <NRf>
:DIGitize <NRf>
:SYNChronize
[:STATe]
:TLEVel <NRf>
:DELay <NRf>
:FAST
:SEARch
:DETect
:TimeOUT
READ[1]?
READ[1]:ARRay?
READ2?
READ2:ARRay?

Command notes (pulse current measurements)

SENSe[1]:FUNCtion 'PCURrent'
SENSe2:FUNCtion 'PCURrent'
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com
Description
Enable or disable pulse current fast readings.
Enable or disable pulse current search.
Enable or disable pulse current detection mode.
Specify length of timeout: 5ms - 32s incrementing in 1ms.
SENSe subsystem for Channel #2 (charger channel):
Select pulse current measurement function.
Pulse current configuration:
Specify average count:
1 to 100 (pulse current measurements), or
1 to 5000 (pulse current digitization).
Select measurement mode; HIGH, LOW or AVERage.
Set integration times:
Integration times set automatically.
Specify integration time (in sec) for high pulse measurements; 33.33e-6
to 0.8333.
Specify integration time (in sec) for low pulse measurements; 33.33e-6 to
0.8333.
Specify integration time (in sec) for average pulse measurements; 33.33e-
6 to 0.8333.
Specify integration time (in sec) for digitizing or burst measurements (B10
firmware and later); 33.33e-6 to 0.8333.
Pulse detection triggering:
Send ON to select pulse current measurements or OFF to select pulse cur-
rent digitization.
Set trigger level in amps: 0.0–5.0
Specify trigger delay in seconds:
0.0–0.1 (pulse current measurements) or
0.0–5.0 (pulse current digitization).
Enable or disable pulse current fast readings.
Enable or disable pulse current search.
Enable or disable pulse current detection mode.
Specify length of timeout: 5ms - 32s incrementing in 1ms.
Trigger and return one reading for Channel #1 (battery channel).
Trigger an array of readings and return them for Channel #1 (battery
channel).
Trigger and return one reading for Channel #2 (charger channel).
Trigger an array of readings and return them for Channel #2 (charger
channel).
This parameter name can also be enclosed in single quotes (as shown above).
Pulse Current Measurements
Applies to battery channel (#1)
Applies to charger channel (#2)
3-15
Default
OFF
ON
OFF
1 (sec)
VOLT
1
HIGH
3.333e-5
3.333e-5
3.333e-5
3.333e-5
ON
0.0
0.0
OFF
ON
OFF
1 (sec)