Sign In
Upload
Manuals
Brands
Keithley Manuals
Power Supply
2280 Series
Keithley 2280 Series Power Supply Manuals
Manuals and User Guides for Keithley 2280 Series Power Supply. We have
4
Keithley 2280 Series Power Supply manuals available for free PDF download: Reference Manual, Quick Start Manual
Keithley 2280 Series Reference Manual (457 pages)
Precision Measurement DC Power Supplies
Brand:
Keithley
| Category:
Power Supply
| Size: 10 MB
Table of Contents
Table of Contents
6
Introduction
15
Welcome
15
Extended Warranty
15
Contact Information
15
Product Documentation and Drivers
16
Organization of Manual Sections
16
Key Features
17
Standard Accessories
18
Optional Accessories
18
Available Services
19
General Ratings
19
General Operation
20
Front-Panel Overview
20
Rear-Panel Overview
22
Front-Panel Overview
22
Front-Panel User Interface
23
Home Screen
23
Menu Overview
33
Adjusting the Backlight Brightness and Timer
46
Installing the System
47
Bumpers
47
Dimensions
48
Power the Instrument on and off
53
Test Connections
56
Front-Panel Connector
57
Rear-Panel Output Mating Connector
58
Two-Wire Local Sense Connection
58
Four-Wire Sense Connection
59
Open Leads Detection
61
Reversed Sense Leads
62
Remote Communications Interfaces
63
Supported Remote Interfaces
64
GPIB Communications
64
LAN Communications
67
USB Communications
83
How to Install the Keithley I/O Layer
89
Set Voltage and Current Limit
90
Constant Voltage (CV) and Constant Current (CC) Mode
91
Select a Measurement Function
93
Select a Specific Measurement Range
94
Selecting a Specific Measurement Range
94
Using Autoranging for Current Measurements
96
Protection
97
Overvoltage Protection
97
Overcurrent Protection
98
Overtemperature Protection
99
Overprotection Error
100
Maximum Voltage Limits
101
Saving Setups
102
Save a User Setup
102
Recall a User Setup
103
Specify a Default Setup
104
Using the Event Log
104
Information Provided for each Event Log Entry
104
Save the Event Log to an External Flash Drive
105
Clear the Event Log
105
System Information
105
Instrument Sounds
106
Resets
106
Reset the Instrument
107
Reset Default Values
107
Functions and Features
115
Changing the Instrument Access Mode
115
Changing the Password
116
Graph
116
Changing the Window Position and Zoom
117
Adjusting the Scale and Offset of the Y-Axis
118
Output Delay, Slew Rate, and Source Delay
119
Output Delay
120
Slew Rate
120
Source Delay
121
Data Buffer
122
Effects of Reset and Power Cycle on Buffer
122
Buffer Fill Status
123
Setting Reading Buffer Size and Buffer Mode
123
Viewing and Saving Buffer Content
126
Clearing the Buffer
132
Digital I/O
133
Digital I/O Port
133
Configuring Digital I/O Lines
137
Trigger Model
139
Idle and Initiate
140
Arm Layer
140
Trigger Layer
140
Source, Source Delay, and Measure Actions
141
Counter
141
Meter Complete
141
Running the Trigger Model
142
Level Trigger
144
Configuring a Voltage Level Trigger
144
Configuring a Current Level Trigger
146
List Operation
148
Configuring a List
149
Importing a List from an External USB Flash Drive
151
Exporting a List to an External USB Flash Drive
152
Configuring and Running a List
152
Aborting a List
163
Sink Operation
164
Measurement Optimization
165
Introduction
165
Optimizing Either Measurement Accuracy or Speed
165
Resolution
166
Nplc
167
Autozero Measurements
169
Displayed Digits
170
Filtering Measurement Data
171
Math Calculations that You Can Apply to Measurements
175
MX+B
175
Setting MX+B Math Operations
176
Relative Offset
177
Establishing a Relative Offset Value
177
Displayed Measurements
179
Select the Source of Readings
181
Application Examples
182
Simple Voltage Output and Current Measurement
182
Equipment Required
182
Set up Remote Communications
182
Device Connections
183
Set the Voltage and Current Limit
183
Configure and Execute a 10-Step Linear List Sweep
185
Equipment Required
185
Set up Remote Communications
185
Device Connections
185
Configure a 10-Step Linear List Sweep
186
Execute a 10-Step Linear List Sweep
187
Perform a Fast Current Load Measurement
188
Equipment Required
188
Set up Remote Communications
188
Device Connections
189
Measure the Fast Current Load Changes
191
Introduction to SCPI Commands
194
Introduction to SCPI
194
Command Messages
194
Command Execution Rules
195
SCPI Command Programming Notes
195
SCPI Command Formatting
195
Using the SCPI Command Reference
198
SCPI Command Reference
202
Common Commands
202
Cls
203
Ese
204
Esr
205
Idn
205
Opc
206
Lang
207
Rcl
207
Rst
208
Sav
208
Sre
209
Stb
209
Trg
210
Tst
211
Wai
211
Abort[N]
212
Configure[N]:<Function
213
Fetch[N]
214
Format:elements
215
Force:trigger
216
Measure[N]:<Function
217
Read[N]
219
ARM Subsystem
220
Arm[:Sequence[N]]:Count
220
Arm[:Sequence[N]]:Source
221
Calculate Subsystem
222
Calculate[1]:<Function>:Format
222
Calculate[1]:<Function>:Kmath:mbfactor
223
Calculate[1]:<Function>:Kmath:mmfactor
224
Calculate[1]:<Function>:Kmath:munits
226
Calculate[1]:<Function>:State
226
Calculate2:Data
228
Calculate2:Format
229
Calculate2:Format:elements
231
Calculate2:Function
232
Calculate2:Immediate
233
Calculate2:State
235
Calibration Subsystem
236
Calibration:protected:cancel
236
Calibration:protected:code
237
Calibration:protected:count
237
Calibration:protected:data
238
Calibration:protected:date
239
Calibration:protected[:DC[N]]:Step<Step
240
Calibration:protected[:DC[N]]:Step<Step>:Data
242
Calibration:protected:save
244
Calibration:protected:state
245
Digital Subsystem
246
Digital:line<N>:Function
246
Digital:line<N>:Manual:input:data
247
Display Subsystem
248
Display:brightness
248
Display:clear
249
Display:screen
250
Display:user:text[:Data]
251
Initiate Subsystem
252
Initiate[N]:Continuous
252
Initiate[N][:Immediate]
253
Mmemory Subsystem
253
Mmemory:load:setup
253
Mmemory:save:setup
254
Output Subsystem
255
Output:delay:falling
255
Output:delay:rising
256
Output:delay:state
257
Output:protection:clear
258
Output:protection:tripped?[<Channel>]
259
Output[:State]
260
Sense Subsystem
261
Sense[N]:Function
261
Sense[N]:<Function>:Average:count
262
Sense[N]:<Function>:Average[:State]
263
Sense[N]:<Function>:Average:tcontrol
264
Sense[N]:<Function>:Average:window
265
Sense[N]:<Function>:Digits
266
Sense[N]:<Function>:Nplcycles
267
Sense[N]:<Function>:Range
268
Sense[N]:<Function>:Range:auto
270
Sense[N]:<Function>:Reference
271
Sense[N]:<Function>:Reference:acquire
272
Sense[N]:<Function>:Reference:state
273
Sense[N]:<Function>:Resolution
274
Source Subsystem
275
[:Source[N]]:Delay
275
[:Source[N]]:Delay:state
276
[:Source[N]]:<Function>:Protection[:Level]
277
[:Source[N]]:<Function>[:Level][:Immediate][:Amplitude]
278
[:Source[N]]:Voltage:limit[:Amplitude]
279
[:Source[N]]:Voltage:slew:rising
280
[:Source[N]]:Voltage:slew:falling
281
[:Source[N]]:List<Listnumber>:<Element
282
[:Source[N]]:List<Listnumber>:<Element>:Append
283
[:Source[N]]:List<Listnumber>:<Element>:Points
284
[:Source[N]]:List:end:zero
285
[:Source[N]]:List:htime
285
[:Source[N]]:List:load:usb
286
[:Source[N]]:List:mcomplete
287
[:Source[N]]:List:rcl
288
[:Source[N]]:List:save:internal
291
[:Source[N]]:List:save:usb
291
[:Source[N]]:List:state
292
Status Subsystem
296
Status:measurement[:Event]
296
Status:measurement:enable
296
Status:measurement:instrument[:Event]
297
Status:measurement:instrument:enable
298
Status:measurement:instrument:isummary[:Event]
299
Status:measurement:instrument:isummary:enable
300
Status:measurement:instrument:isummary:condition
301
Status:operation[:Event]
301
Status:operation:enable
302
Status:operation:instrument[:Event]
302
Status:operation:instrument:enable
303
Status:operation:instrument:isummary[:Event]
304
Status:operation:instrument:isummary:enable
305
Status:operation:instrument:isummary:condition
306
Status:preset
306
Status:questionable[:Event]
307
Status:questionable:enable
308
Status:questionable:instrument[:Event]
308
Status:questionable:instrument:enable
309
Status:questionable:instrument:isummary[:Event]
310
Status:questionable:instrument:isummary:enable
310
Status:questionable:instrument:isummary:condition
311
System Subsystem
312
System:azero[N][:State]
312
System:beeper:error[:State]
313
System:communication:abort
314
System:communication:lan:configure
315
System:communication:lan:macaddress
316
System:date
316
System:error
317
System:error:clear
317
System:error:code
318
System:error:count
318
System:eventlog:save
319
System:gpib:address
319
System:kclick
320
System:local
321
System:lfrequency
322
System:password:lock
322
System:password:mode
323
System:password:new
323
System:password:unlock
324
System:posetup:state
325
System:preset
325
System:rwlock
326
System:time
327
System:version
327
Trace Subsystem
328
Data[N]:Clear
328
Data[N]:Clear:auto
328
Data[N]:Data
329
Data[N]:Data:selected
331
Data[N]:Feed
333
Data[N]:Feed:control
334
Data[N]:Points
335
Data[N]:Points:actual
335
Trace[N]:Clear
336
Trace[N]:Clear:auto
336
Trace[N]:Data
337
Trace[N]:Data:selected
339
Trace[N]:Feed
341
Trace[N]:Feed:control
342
Trace[N]:Points
343
Trace[N]:Points:actual
343
Trace[N]:Save
344
Trace[N]:Trigger:current:direction
345
Trace[N]:Trigger:current[:Level]
345
Trace[N]:Trigger:current:state
346
Trace[N]:Trigger:occur
347
Trace[N]:Trigger:offset
347
Trace[N]:Trigger:voltage:direction
348
Trace[N]:Trigger:voltage[:Level]
348
Trace[N]:Trigger:voltage:state
349
Trigger Subsystem
350
Trigger[:Sequence[N]]:Count
350
Trigger[:Sequence[N]]:Sample:count
351
Trigger[:Sequence[N]]:Source
352
Troubleshooting Guide
353
Introduction
353
Contacting Support
353
What to Do if the Power Supply Does Not Turn on
354
LAN Troubleshooting Suggestions
355
Error Summary
356
Next Steps
362
Additional Series 2280 Information
362
Maintenance
363
Introduction
363
Line Fuse Replacement
363
Upgrading the Firmware
364
From the Front Panel
365
Perform DIN VDE 701 Test
366
Cleaning the Front-Panel Display
366
Verification
367
Overview
367
Test Record
368
Performance Verification Procedures
383
Required Equipment
384
DC Voltage Setting Accuracy with Remote Sense
386
Check DC Voltage Setting Accuracy with Remote Sense
387
DC Voltage Setting Accuracy Without Remote Sense
388
Check DC Voltage Readback Accuracy Without Remote Sense
389
Check DC Voltage Line Regulation
391
DC Voltage Load Regulation
393
Check DC Overvoltage Protection
394
Check DC Current Accuracy
395
DC Overvoltage Protection
395
DC Current Accuracy
396
Check DC Current Readback Accuracy (10 a and 1 a Ranges)
397
DC Current Readback Accuracy
398
Check DC Current Readback Accuracy (100 Ma and 10 Ma Ranges
399
Check DC Current Line Regulation
401
Check DC Current Load Regulation
403
Check Overcurrent Protection
404
Check Voltage Noise (20 Mhz
405
Check Current Noise (20 Mhz
407
Calibration and Adjustment
408
Overview
408
Environmental Conditions
408
Warmup Period
409
Line Power
409
Calibration Considerations
409
Calibration Cycle
409
Appendix C
409
Environmental Conditions
409
Required Equipment
410
Characterization Shunts
411
Calibration Connection
413
Voltage Calibration Connections
414
Current Calibration Connections
415
Front-Panel Calibration Procedure
417
Voltage Calibration
418
Low-Current Calibration
419
High-Current Calibration
420
Saving Calibration Constants from the Front Panel
422
Remote Calibration Procedure
423
Remote Voltage Calibration
424
Remote Low-Current Calibration
425
Remote High-Current Calibration
427
Saving Calibration Constants Using SCPI Commands
430
Configure the Calibration Date
430
Exit the Calibration Procedure Using SCPI Commands
431
Change the Calibration Password
431
Calibration Constants
432
Status Model
434
Status Model
435
Programming and Reading Registers
438
Programming Enable Registers
438
Reading the Registers
439
Clearing the Registers
439
Status Byte and Service Request
440
Status Byte Register
440
Service Request Enable Register
442
Status Register Sets
442
Register Bit Descriptions
442
Event Registers
453
Event Enable Registers
453
Condition Registers
453
Queues
453
Output Queue
454
Error Queue
454
Serial Polling and SRQ
454
Status Model Programming Examples
455
SRQ When Trigger Model Is Finished
456
Advertisement
Keithley 2280 Series Reference Manual (399 pages)
Precision Measurement
Brand:
Keithley
| Category:
Power Supply
| Size: 10 MB
Table of Contents
Safety Precautions
4
Table of Contents
6
Introduction
16
Welcome
16
Extended Warranty
16
Contact Information
16
CD-ROM Contents
17
Organization of Manual Sections
17
Key Features
18
Standard Accessories
18
Optional Accessories
19
Available Services
20
General Ratings
20
General Operation
22
Front-Panel Overview
22
Rear-Panel Overview
24
Front-Panel User Interface
25
Home Screens
25
Menu Overview
31
System Menu
39
Adjusting the Backlight Brightness and Timer
42
Installing the System
43
Handle and Bumpers
43
Dimensions
48
Power the Instrument on and off
52
Test Connections
54
Front-Panel Connector
55
Rear-Panel Output Mating Connector
56
Two-Wire Local Sense Connection
57
Four-Wire Sense Connection
57
Open Leads Detection
58
Reverse Sense Leads
60
Remote Communication Interfaces
61
Supported Remote Interfaces
61
GPIB Communication
61
Set the Gpib Address
63
LAN Communication
64
USB Communications
76
How to Install the Keithley I/O Layer
82
Set Voltage and Current Limit
83
Constant Voltage (CV) and Constant Current (CC) Mode
84
Select a Measurement Function
86
Select a Specific Measurement Range
86
Selecting a Specific Measurement Range
87
Using Autoranging for Current Measurements
87
Protection
88
Overvoltage Protection
88
Overcurrent Protection
89
Overtemperature Protection
90
Overprotection Error
91
Maximum Voltage Limits
91
Saving Setups
92
Save a User Setup
93
Recall a User Setup
94
Specify a Default Setup
94
Using the Event Log
95
Information Provided for each Event Log Entry
95
Save the Event Log to an External Flash Drive
95
Clear the Event Log
95
System Information
96
Instrument Sounds
96
Resets
97
Reset the Instrument
97
Functions and Features
98
Changing the Instrument Access Mode
98
Changing the Password
99
Graph
99
Changing the Window Position and Zoom
100
Adjusting the Scale and Offset of Y-Axis
101
Output Delay, Slew Rate, and Source Delay
102
Output Delay
102
Slew Rate
103
Source Delay
103
Reading Buffer
104
Effects of Reset and Power Cycle on Buffer
104
Buffer Fill Status
104
Setting Reading Buffer Size and Buffer Mode
105
Viewing and Saving Buffer Content
106
Configuring the Statistics Applied to Data in the Buffer
109
Clearing Buffer
112
Automatically Clearing Buffer
113
Digital I/O
113
Digital I/O Port
113
Configuring Digital I/O Lines
116
Trigger Model
118
Idle and Initiate
120
Arm Layer
120
Trigger Layer
120
Source, Source Delay and Measure Actions
120
Counter
121
Meter Complete
121
Running the Trigger Model
121
Level Trigger
123
Configuring a Voltage Level Trigger
123
Configuring a Current Level Trigger
125
List Operation
127
Configuring a List
128
Importing a List from an External USB Flash Drive
130
Exporting a List to an External USB Flash Drive
131
Running a List
131
Aborting a List
140
Sink Operation
141
Reset Default Values
141
Default Value
142
Measurement Optimization
150
Introduction
150
Optimizing Either Measurement Accuracy or Speed
150
Resolution
151
Nplc
152
Autozero Measurements
153
Displayed Digits
154
Filtering Measurement Data
155
Math Calculations that You Can Apply to Measurements
159
MX+B
159
Setting MX+B Math Operations
159
Relative Offset
160
Establishing a Relative Offset Value
161
Displayed Measurements
162
Select the Source of Readings
163
Application Examples
166
Simple Voltage Output and Current Measurement
166
Equipment Required
166
Set up Remote Communications
166
Device Connections
167
Set the Voltage and Current Limit
167
Configure and Execute a 10-Step Linear List Sweep
168
Equipment Required
168
Set up Remote Communications
169
Device Connections
169
Configure a 10-Step Linear List Sweep
169
Execute a 10-Step Linear List Sweep
170
Perform a Fast Current Load Measurement
171
Equipment Required
172
Set up Remote Communications
172
Device Connections
173
Measure the Fast Current Load Changes
174
Introduction to SCPI Commands
178
Introduction to SCPI
178
Command Messages
178
Command Execution Rules
179
SCPI Command Programming Notes
179
SCPI Command Formatting
179
Using the SCPI Command Reference
181
Command Details
183
Common Commands
186
SCPI Command Reference
186
Cls
187
Ese
187
Esr
188
Idn
189
Opc
189
Lang
190
Rcl
190
Rst
191
Sav
191
Sre
192
Stb
193
Trg
194
Tst
194
Wai
195
Abort[N]
196
Configure[N]:<Function
196
Fetch[N]
197
Format:elements
198
Force:trigger
200
Measure[N]:<Function
201
Read[N]
202
ARM Subsystem
202
Arm[:Sequence[N]]:Count
203
Arm[:Sequence[N]]:Source
203
Calculate Subsystem
204
Calculate[1]:<Function>:Format
204
Calculate[1]:<Function>:Kmath:mbfactor
205
Calculate[1]:<Function>:Kmath:mmfactor
206
Calculate[1]:<Function>:Kmath:munits
207
Calculate[1]:<Function>:State
207
Calculate2:Data
209
Calculate2:Format
210
Calculate2:Format:elements
212
Calculate2:Function
213
Calculate2:Immediate
214
Calculate2:State
216
Calibration Subsystem
216
Calibration:protected:cancel
217
Calibration:protected:code
217
Calibration:protected:count
218
Calibration:protected:data
218
Calibration:protected:date
219
Calibration:protected[:DC[N]]:Step<Step
220
Calibration:protected[:DC[N]]:Step<Step>:Data
222
Calibration:protected:save
224
Calibration:protected:state
225
Digital Subsystem
225
Digital:line<N>:Function
226
Digital:line<N>:Manual:input:data
226
Display Subsystem
227
Display:brightness
227
Display:clear
228
Display:screen
228
Display:user:text[:Data]
229
Initiate Subsystem
229
Initiate[N]:Continuous
230
Initiate[N][:Immediate]
230
Mmemory Subsystem
231
Mmemory:load:setup
231
Mmemory:save:setup
231
Output Subsystem
232
Output:delay:falling
232
Output:delay:rising
233
Output:delay:state
234
Output:protection:clear
234
Output:protection:tripped
235
Output[:State]
236
Sense Subsystem
236
Sense[N]:Function
236
Sense[N]:<Function>:Average:count
237
Sense[N]:<Function>:Average[:State]
238
Sense[N]:<Function>:Average:tcontrol
239
Sense[N]:<Function>:Average:window
240
Sense[N]:<Function>:Digits
241
Sense[N]:<Function>:Nplcycles
242
Sense[N]:<Function>:Range
243
Sense[N]:<Function>:Range:auto
244
Sense[N]:<Function>:Reference
245
Sense[N]:<Function>:Reference:acquire
246
Sense[N]:<Function>:Reference:state
247
Sense[N]:<Function>:Resolution
248
Source Subsystem
248
[:Source[N]]:Delay
249
[:Source[N]]:Delay:state
249
[:Source[N]]:<Function>:Protection[:Level]
250
[:Source[N]]:<Function>[:Level][:Immediate][:Amplitude]
251
[:Source[N]]:Voltage:limit[:Amplitude]
252
[:Source[N]]:Voltage:slew:rising
252
[:Source[N]]:Voltage:slew:falling
253
[:Source[N]]:List<List Number>:<Element
254
[:Source[N]]:List<List Number>:<Element>:Append
255
[:Source[N]]:List<List Number>:<Element>:Points
256
[:Source[N]]:List:end:zero
256
[:Source[N]]:List:htime
257
[:Source[N]]:List:load:usb
257
[:Source[N]]:List:mcomplete
258
[:Source[N]]:List:rcl
259
[:Source[N]]:List:save:internal
263
[:Source[N]]:List:save:usb
263
[:Source[N]]:List:state
264
Status Subsystem
267
Status:measurement[:Event]
268
Status:measurement:enable
268
Status:measurement:instrument[:Event]
269
Status:measurement:instrument:enable
269
Status:measurement:instrument:isummary[:Event]
270
Status:measurement:instrument:isummary:enable
270
Status:measurement:instrument:isummary:condition
271
Status:operation[:Event]
272
Status:operation:enable
272
Status:operation:instrument[:Event]
273
Status:operation:instrument:enable
273
Status:operation:instrument:isummary[:Event]
274
Status:operation:instrument:isummary:enable
274
Status:operation:instrument:isummary:condition
275
Status:preset
276
Status:questionable[:Event]
276
Status:questionable:enable
277
Status:questionable:instrument[:Event]
277
Status:questionable:instrument:enable
278
Status:questionable:instrument:isummary[:Event]
279
Status:questionable:instrument:isummary:enable
279
Status:questionable:instrument:isummary:condition
280
System Subsystem
280
System:azero[N][:State]
281
System:beeper:error[:State]
281
System:communication:abort
282
System:communication:lan:configure
283
System:communication:lan:macaddress
284
System:date
284
System:error
285
System:error:clear
285
System:error:code[:Next]
286
System:error:count
286
System:eventlog:save
287
System:gpib:address
287
System:kclick
288
System:local
289
System:lfrequency
289
System:password:lock
290
System:password:mode
290
System:password:new
291
System:password:unlock
291
System:posetup:state
292
System:preset
292
System:rwlock
293
System:time
294
System:version
294
Trace Subsystem
294
Trace[N]:Clear or :Data[N]:Clear
295
Trace[N]:Clear:auto or :Data[N]:Clear:auto
295
Trace[N]:Data? or :Data[N]:Data
296
Trace[N]:Data:selected? or :Data[N]:Data:selected
297
Trace[N]:Feed or :Data[N]:Feed
299
Trace[N]:Feed:control or :Data[N]:Feed:control
300
Trace[N]:Points or :Data[N]:Points
301
Trace[N]:Points:actual? or :Data[N]:Points:actual
301
Trace[N]:Save or :Data[N]:Save
302
Trace[N]:Trigger:current:direction
303
Trace[N]:Trigger:current[:Level]
303
Trace[N]:Trigger:current:state
304
Trace[N]:Trigger:occur
305
Trace[N]:Trigger:offset
305
Trace[N]:Trigger:voltage:direction
306
Trace[N]:Trigger:voltage[:Level]
307
Trace[N]:Trigger:voltage:state
307
Trigger Subsystem
308
Trigger[:Sequence[N]]:Count
308
Trigger[:Sequence[N]]:Sample:count
309
Trigger[:Sequence[N]]:Source
309
Introduction
312
Contacting Support
312
Troubleshooting Guide
312
What to Do if the Power Supply Does Not Turn on
313
LAN Troubleshooting Suggestions
313
Error Summary
314
Next Steps
320
Additional Series 2280 Information
320
Maintenance
322
Introduction
322
Upgrading the Firmware
322
Upgrading the Firmware
323
From the Front Panel
324
Cleaning the Front-Panel Display
325
Verification
326
Overview
326
Test Record
326
DC Voltage Setting Accuracy with Remote Sense
327
DC Voltage Setting Accuracy Without Remote Sense
328
DC Voltage Readback Accuracy with Remote Sense
329
DC Voltage Readback Accuracy Without Remote Sense
329
DC Voltage Line Regulation
329
DC Voltage Load Regulation
330
DC Overvoltage Protection
330
DC Current Accuracy
330
DC Current Readback Accuracy
331
DC Current Line Regulation
332
DC Current Load Regulation
332
DC Overcurrent Protection
333
Voltage Noise at 20 Mhz
333
Current Noise at 20 Mhz
333
Performance Verification Procedures
333
Performance Verification Conditions
334
Required Equipment
335
Check DC Voltage Setting Readback Accuracy with Remote Sense
335
Check DC Voltage Setting Accuracy Without Remote Sense
337
Check DC Voltage Readback Accuracy Without Remote Sense
339
Check DC Voltage Line Regulation
341
Check DC Voltage Load Regulation
343
Check DC Overvoltage Protection
344
Check DC Current Accuracy
344
Check DC Current Readback Accuracy (10 a and 1 a Ranges
345
Check DC Current Readback Accuracy (100 Ma and 10 Ma Ranges
346
Check DC Current Line Regulation
349
Check DC Current Load Regulation
351
Check Overcurrent Protection
352
Check Voltage Noise (20 Mhz
352
Check Current Noise (20 Mhz
354
Calibration
356
Overview
356
Environmental Conditions
356
Warmup Period
357
Line Power
357
Calibration Considerations
357
Calibration Cycle
357
In this Appendix:
357
Appendix C
357
Environmental Conditions
357
Calibration Connection
361
Voltage Calibration Connection
361
Current Calibration Connections
363
Required Equipment
361
Front-Panel Calibration Procedure
364
Voltage Calibration
365
Low-Current Calibration
366
High-Current Calibration
367
Saving Calibration Constants from the Front Panel
368
Remote Calibration Procedure
369
Remote Voltage Calibration
369
Remote Low-Current Calibration
371
Remote High-Current Calibration
372
Saving Calibration Constants Using SCPI Comands
375
Configure the Calibration Date
375
Exit the Calibration Procedure Using SCPI Commands
375
Change the Calibration Password
376
Calibration Constants
377
Status Model
380
Overview
380
Programming and Reading Registers
383
Programming Enable Registers
383
Reading the Registers
384
Clearing the Registers
384
Status Byte and Service Request
384
Status Byte Register
385
Service Request Enable Register
386
Status Register Sets
386
Register Bit Descriptions
387
Operation Event Register
388
Event Registers
396
Event Enable Registers
396
Condition Registers
396
Queues
396
Output Queue
396
Error Queue
397
Serial Polling and SRQ
397
Status Model Programming Examples
397
SRQ When Reading Buffer Becomes Full
397
SRQ When Trigger Model Is Finished
398
KEITHLEY 2280 Series Quick Start Manual (23 pages)
Precision Measurement DC Power Supplies
Brand:
KEITHLEY
| Category:
Power Supply
| Size: 1 MB
Table of Contents
Safety Precautions
2
Power and Environmental Specifications
4
CD-Rom Contents
5
Unpack and Inspect the Instrument
6
Connect the Instrument
8
Important Test System Safety Information
8
Install the Instrument
9
Power up the Instrument
9
To Connect Line Power
10
Connections for Testing
11
Two-Wire Connection
11
Four-Wire Remote Sense Connection
13
Overview of the Front-Panel Options
14
ENTER and EXIT Keys
14
Front-Panel User Interface Overview
14
Home Screen Overview
15
Menu Screen Overview
15
Simple Voltage Output and Current Measurement
16
Specify a Measurement Range
18
Configure and Execute a 10-Step Linear List Sweep
19
Next Steps
21
Advertisement
Keithley 2280 Series Quick Start Manual (23 pages)
Precision Measurement DC Power Supplies
Brand:
Keithley
| Category:
Power Supply
| Size: 1 MB
Table of Contents
Safety Precautions
2
Power and Environmental Specifications
4
Unpack and Inspect the Instrument
6
Connect the Instrument
7
Important Test System Safety Information
7
Install the Instrument
8
Power up the Instrument
9
Turn on the Instrument
10
Connections for Testing
10
Two-Wire Connections
10
Four-Wire Remote Sense Connection
12
Overview of the Front-Panel Options
13
Front-Panel User Interface Overview
14
Home Screen Overview
14
Menu Screen Overview
15
Voltage Output and Current Measurement
16
Specify a Measurement Range
18
Configure and Execute a 10-Step Linear List Sweep
19
Next Steps
21
Advertisement
Related Products
Keithley 2281S Series
Keithley 228A
Keithley 2280S-32-6
Keithley 2280S-60-3
Keithley 2281S-20-6
Keithley 2290-10
Keithley 2260B Series
Keithley 2260B-250-9
Keithley 2230-30-1
Keithley 2230 Series
Keithley Categories
Measuring Instruments
Multimeter
Test Equipment
Power Supply
Switch
More Keithley Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL