Sign In
Upload
Manuals
Brands
Keithley Manuals
Power Supply
2231A-30-3
Keithley 2231A-30-3 Power Supply Manuals
Manuals and User Guides for Keithley 2231A-30-3 Power Supply. We have
1
Keithley 2231A-30-3 Power Supply manual available for free PDF download: Reference Manual
Keithley 2231A-30-3 Reference Manual (75 pages)
Triple-Channel DC Power Supply
Brand:
Keithley
| Category:
Power Supply
| Size: 1 MB
Table of Contents
Table of Contents
6
Introduction
10
Welcome
10
Extended Warranty
10
Contact Information
10
CD-ROM Contents
11
Key Features
11
Standard Accessories
11
Optional Accessories
12
Available Services
12
General Ratings
12
Quick Reference
14
Front-Panel Overview
14
Rear Panel Overview
15
Installing the System
15
Dimensions
15
Adjust the Carrying Handle
16
Power the Instrument on or off
17
Self-Test Procedure
19
Check the Output
20
Voltage Output Check
20
Current Output Check
21
What to Do if the Power Supply Does Not Turn on
21
General Operation
24
Front-Panel Operation Overview
24
Panel Description
25
Indicator Description
26
Basic Settings
26
Set the Voltage Output or Voltage Limit for a Specific Channel
26
Set the Current Output or Current Limit for a Specific Channel
26
Save and Recall the Setups
26
Menu Description
27
Default Set
27
Enable Channels
28
Protection Settings
28
Track CH1/CH2
29
Combine CH1+CH2
30
User Settings
32
System Info
33
Overtemperature Protection (OTP)
34
Overtemperature Protection
34
Remote Communication
36
Communication Interface
36
SCPI Command Reference
38
Common Commands
39
Cls
39
Ese
39
Esr
40
Idn
40
Opc
40
Rst
40
Sre
41
Stb
41
Trg
41
Sav
42
Rcl
42
Tst
42
Wai
42
Psc
43
Apply Subsystem
43
[Source:]Apply
43
[Source:]Apply:voltage[:Level][:Immediate][:Amplitude]
43
[Source:]Apply:current[:Level][:Immediate][:Amplitude]
44
Calibration Subsystem
44
Calibration:secure:[State]
44
Calibrate:voltage:level
44
Calibrate:voltage[:Data] <Numeric Value
45
Calibrate:current:level
45
Calibrate:current[:Data] {<Numeric Value
45
Calibration:save
46
Calibration:initital
46
Calibrate:string
46
Display Subsystem
46
Display[:Window][:State]
46
Display[:Window]:Text[:Data]
47
Display[:Window]:Text:clear
47
Instrument Subsystem
47
Instrument[:Select]
47
Instrument:nselect
48
Instrument:combine:series
48
Instrument:combine:parallel
48
Instrument:combine:track
49
Instrument:combine:off
49
Instrument:couple[:Trigger]
49
Measure Subsystem
49
Measure[:Scalar]:Voltage[:DC]
50
Fetch[:Voltage][:DC]
50
Measure[:Scalar]:Current[:DC]
50
Fetch:current[:DC]
50
Measure[:Scalar]:Power[:DC]
50
Fetch:power[:DC]
50
Output Subsystem
51
Output[:State][:All]
51
Channel:output[:State]
51
Output:enable
51
Output:timer[:State]
52
Output:timer:delay
52
Output:track[:State]
52
Output:series[:State]
53
Output: Parallel [:State]
53
System Subsystem
54
System:error
54
System:version
54
System:remote
54
System:local
54
System:rwlock
55
System:module
55
System:beeper
55
Status Subsystem
56
Status:questionable[:Event]
56
Status:questionable:enable
56
Status:questionable:condition
56
Status:preset
57
Status:questionable:instrument[:Event]
57
Status:questionable:instrument:enable
57
Status:questionable:instrument:isummary<X>[:Event]
57
Status:questionable:instrument:isummary<X>:Enable
58
Status:questionable:instrument:isummary<X>:Condition
58
Status:operation[:Event]
58
Status:operation:condition
59
Status:operation:enable
59
Status:operation:instrument[:Event]
59
Status:operation:instrument:enable
60
Status:operation:instrument:isummary<X>[:Event]
60
Status:operation:instrument:isummary<X>:Enable
60
Status:operation:instrument:isummary<X>:Condition
60
Source Subsystem
61
[Source:]Channel:output[:State]
61
[Source:]Current[:Level][:Immediate][:Amplitude]
61
[Source:]Current[:Level]:Up[:Immediate][:Amplitude]
61
[Source:]Current[:Level]:Down[:Immediate][:Amplitude]
62
[Source:]Current[:Level][:Immediate]:Step[:Increment]
62
[Source:]Current[:Level]:Triggered[:Immediate][:Increment]
62
[Source:]Voltage[:Level][:Immediate][:Amplitude]
63
[Source:]Voltage[:Level]:Up[:Immediate][:Amplitude]
63
[Source:]Voltage[:Level]:Down[:Immediate][:Amplitude]
63
[Source:]Voltage[:Level][:Immediate]:Step[:Increment]
64
[Source:]Voltage[:Level]:Triggered[:Immediate][:Increment]
64
[Source:]Voltage:limit[:Level]
64
[Source:]Voltage:limit:state
65
Status Model
66
Error Messages
68
Additional Information
70
Additional Model 2231A-30-3 Information
70
Advertisement
Advertisement
Related Products
Keithley 2230-30-1
Keithley 2230J-30-1
Keithley 2230G-30-1
Keithley 2230GJ-30-1
Keithley 2230G-30-6
Keithley 2230G-60-3
Keithley 2230 Series
Keithley 2230-30-6
Keithley 2230-60-3
Keithley 2230-30-3
Keithley Categories
Measuring Instruments
Multimeter
Test Equipment
Power Supply
Switch
More Keithley Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL