1 NOV. '87
3-2 CLEANING BLADE REPLACEMENT
1. Remove the cleaning unit [A], and remove the cleaning blade [B] (1
shoulder screw).
2. Replace the cleaning blade being careful not to touch the edge of the
blade.
After installing the blade, make sure it swivels from side to side.