1-4 EXPOSURE LAMP POSITION ADJUSTMENT
1. Turn off the main switch.
2. Remove the exposure glass (see 1-1 Exposure Glass Removal).
3. Move
the 1st scanner so that the exposure lamp is located
area of the mylar.
4. For 115 volt machines, remove the front and rear exposure lamp terminal
covers [A] (1 screw each).
- Horizontal Adjustment -
5. View the exposure lamp filament through the front and rear sight holes
[B]. The filament [C] should be directly beneath the sight holes.
6. To correct the position of the filament, turn the front and rear adjusting
screws [D].
3-5
1 Nov. '87
in the central