Ricoh FT3320 Service Training Manual page 193

All in one printer
Hide thumbs Also See for FT3320:
Table of Contents

Advertisement

1
N o v
'87
,
=
8. If the voltage is incorrect, adjust VR101 on the main PCB in order to ob-
tain the correct amount.
9. Press the "C/S" key, turn off the main switch and DPS 101-5.
after being on for 20
NOTE: The exposure lamp has a safety shut-off
seconds.
METHOD B: Reading from a Digital Multimeter
10. Hook up the multimeter leads as follows:
a) positive lead to TPI 02
b) negative lead to TPI03 (GND).
11. Repeat procedures 6 to 9, noting the reading in the multimeter.
3-6s