2-3 DIP Switches
DIP Switch
101-1
101-2
101-3
101-4
101-5
101-6
NOTE: The lead edge registration adjustment interval is 1.2 mm per step,
See the following table:
DPSI02
DIP Switch
102-1
102-2
102-3
102-4
Normal
Lead edge registration adjustment 1
Lead edge registration adjustment 2
Lead edge registration adjustment 3
Lead edge registration adjustment
OFF
Test Mode
Free Run. (When in Free Run Mode,
OFF
the paper feed solenoid, total
counter, and paper lift clutch do
not work. )
Normal
Selects ID sensor pattern bias level.
(See the following table.)
OFF
Selects ID sensor pattern bias level.
(See the following table.)
OFF
Selects the fusing temperature level.
(OFF = 185°C, ON = 175°C)
OFF
Warm-up idle. If ON the machine
idles for 8 minutes after warm-up.
(During warm-up idle, the cleaning
solenoid is energized and the devel-
opment bias is fixed at 250 volts.)
Function
Function
2-5