1 Nov. '87
9-3 HORIZONTAL MAGNIFICATION ADJUSTMENT
1. Make a few copies using an OS-A4 test chart [A] as the original and
check the horizontal magnification.
magnification is out of specification, adjust it in the following man-
2. If the
ner:
a)
Remove the rear and upper covers.
Move the 1st scanner so that the wire clamp [B] is accessible
b)
between the main PCB and the optics cooling fan assembly.
c)
Loosen the wire clamp (1 screw).
Move the 1st scanner to the right to enlarge the
d)
the left to reduce it (as viewed from the rear of the copier).
Tighten the wire clamp screw and check the magnification again,
e)
3-66